HP LH4r HP Netserver LH 3000 Installation Guide - Page 154

Tools Required, Installing the Slides

Page 154 highlights

Chapter 13 Alternative Rack Mounting Tools Required The following tools are required to install the NetServer: • Small adjustable open-end wrench • Torx 15 and 25 drivers • Phillips head screwdriver • Hewlett-Packard Systems Rack template • Tape or a marker pen to mark mounting locations Installing the Slides The following steps and illustrations describe how install slides for mounting a NetServer. Marking the Columns Mark the mounting location of the NetServer and mounting holes on each column of the rack as described. NOTE The EIA unit marks are stamped in the sheet metal of the columns. Use the rack template to mark the correct holes for mounting (on all four columns). Marking Front Columns Mark the slide mounting holes on the front columns. 1. Mark the baseline (bottom) of the NetServer at an EIA unit mark on the column. 2. Hold the bottom of the rack template at the baseline. Mark the top of NetServer (8 EIA units counted up from the baseline). 3. Mark the slide screw mounting holes (holes 20 and 22 counted up from the baseline). 4. Mark the second front column by repeating steps 1 through 3. 146

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182

Chapter 13
Alternative Rack Mounting
146
Tools Required
The following tools are required to install the NetServer:
Small adjustable open-end wrench
Torx
15 and 25 drivers
Phillips head screwdriver
Hewlett-Packard Systems Rack template
Tape or a marker pen to mark mounting locations
Installing the Slides
The following steps and illustrations describe how install slides for mounting a
NetServer.
Marking the Columns
Mark the mounting location of the NetServer and mounting holes on each column
of the rack as described.
NOTE
The EIA unit marks are stamped in the sheet metal of the
columns. Use the rack template to mark the correct holes for
mounting (on all four columns).
Marking Front Columns
Mark the slide mounting holes on the front columns.
1.
Mark the baseline (bottom) of the NetServer at an EIA unit mark on the
column.
2.
Hold the bottom of the rack template at the baseline. Mark the top of
NetServer (8 EIA units counted up from the baseline).
3.
Mark the slide screw mounting holes (holes 20 and 22 counted up from the
baseline).
4.
Mark the second front column by repeating steps 1 through 3.