HP Surestore Tape Library Model 20/700 HP Surestore Tape Library Model 20/700 - Page 101
CAP States, EMPTY, UNKNOWN, UNREADABLE, CAP A B Open, CAP A B Transition, CAP A B Unknown
View all HP Surestore Tape Library Model 20/700 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 101 highlights
Table 9 Table 10 CAP Magazine Slot Status Messages Message EMPTY UNKNOWN UNREADABLE Explanation This magazine slot does not contain a cartridge. This magazine slot contains a cartridge, but the library has not yet performed the necessary audit to identify the cartridge. This magazine slot contains a cartridge, but the camera could not read the cartridge's VOLSER label. CAP States When exporting or importing cartridges through the CAPs, the following CAP states may be displayed: CAP States State CAP A (B) Open CAP A (B) Closed CAP A (B) Transition CAP A (B) Unknown Explanation Specified CAP is open for exporting or importing of cartridges Specified CAP is closed and locked Specified CAP is stalled during an open or close transition. This message indicates a problem and an error is posted to the FSC log. The specified CAP is in an unknown state. Consult the FSC logs. 100 Operating in Automated Mode Chapter 4