Page 73 highlights
4. Press the [SELECT] button. The Lib Config Menu will appear and the cursor will line up with LIB SCSI I/F CONFIG. 5. Press the [SELECT] button. The Lib SCSI I/F Config Menu will appear. (This menu also displays the type of SCSI interface: differential or single-ended.) 6. Press the arrow buttons until the cursor underscores SCSI ID. 7. Press the [SELECT] button. The Set Lib SCSI ID Menu will appear. 8. Press the up and down arrow buttons to select the correct ID. 9. Press the [SELECT] button to save the changes. (You may press the [MENU] button to abort.) 10. If the library SCSI ID is the only configuration value you wish to set at this time, press the [RESET] button. If you wish to set other configuration values before you reset the library, continue with the next section. 72 Entering Configuration Data Chapter 3
![](/manual_guide/products/hewlettpackard-surestore-tape-library-model-20700-hp-surestore-tape-library-model-20700-user039s-guide-550878d/73.png)