Core I/O Location, Core I/O Card Bottom with DIP Switch Location Shown
View all HP rp8420 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 150 highlights
Figure 6-42 Core I/O Location The core I/O card has a DIP switch positioned at the location shown in Figure 6-43: Core I/O Card Bottom with DIP Switch Location Shown, that must be set prior to operation of the server. NOTE: The Server Expansion Unit (SEU) uses the same core I/O card with DIP switch as the host server. The DIP switch on the core I/O cards installed in the SEU must be set to the same position as the host server. Figure 6-43 Core I/O Card Bottom with DIP Switch Location Shown Refer to the following table for the correct switch settings. System HP 9000 rp8400 server All other servers Dip Switch 1 On Off 150 Removal and Replacement Dip Switch 2 On Off
Figure 6-42 Core I/O Location
The core I/O card has a DIP switch positioned at the location shown in
Figure 6-43: Core I/O
Card Bottom with DIP Switch Location Shown
, that must be set prior to operation of the server.
NOTE:
The Server Expansion Unit (SEU) uses the same core I/O card with DIP switch as the
host server. The DIP switch on the core I/O cards installed in the SEU must be set to the same
position as the host server.
Figure 6-43 Core I/O Card Bottom with DIP Switch Location Shown
Refer to the following table for the correct switch settings.
Dip Switch 2
Dip Switch 1
System
On
On
HP 9000 rp8400 server
Off
Off
All other servers