IBM 4851 514 Service Guide - Page 65
Troubleshooting, common, problems
View all IBM 4851 514 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 65 highlights
Updated October, 2008 Chapter 4. Troubleshooting common problems This section describes several common problems and explains what to do. Table 9. Symptoms and actions If the problem is... Here's what to do. No green power light on the tower unit. 1. Ensure that the system unit is plugged into a working electrical outlet and replug the power cable at the power supply. 2. Verify that the display cable is plugged properly into the display and into the system board. 3. Verify the power cable is plugged into the system board connectors P1 and P2. 4. Replace the power supply. See "Power supply - removing and replacing" on page 68. 5. Replace the system board. See "System board - removing and replacing" on page 66. Operator display exhibits the following conditions (with the green LED on): v Blank screen v No cursor available v Screen is unreadable v Other display problems 1. Adjust the brightness control at the bottom right side of the display. 2. Ensure that the operator display cable is securely connected. 3. Switch unit off and back on. 4. Run the operator display test using the diagnostic USB memory key. 5. Open the tablet and check that all of the cable connections are secure. 6. Replace the LCD assembly. See "LCD assembly removal and replacement" on page 59. 7. If condition persists, replace the tablet card. See "Control card - removal and replacement" on page 57. 8. If condition persists, replace the system board. See "System board - removing and replacing" on page 66. Operator display backlight: dark, dim, or partially lit. 1. Adjust the brightness using the button located on the front of the display. 2. Ensure operator display cable is securely attached under display tablet and at system board. 3. Open the tablet and check that all of the cable connections are secure. Reboot the system. 4. If only half of the display is lit, replace the LCD assembly. See "LCD assembly - removal and replacement" on page 59. 5. If condition persists, replace the system board. See "System board - removing and replacing" on page 66. 6. If condition persists (the operator display backlight is dark dim or partially lit); however, the HDD light shows activity; and the POST bleeps completion upon reboot, replace the LCD assembly. See "LCD assembly - removal and replacement" on page 59. © Copyright IBM Corp. 2005, 2008 49