Icom IC-80AD Instruction Manual - Page 113
Scan edges programming
View all Icom IC-80AD manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 113 highlights
SCAN OPERATION 10 N Scan edges programming Scan edges can be programmed in the same manner as memory channels. Scan edges are programmed into scan edges, 0A/0B to 24A/24B, in memory channels. q Push [V/MHz] to select VFO mode. w Set the desired frequency: ± Select the desired band with [BAND]. ± Set the desired frequency with [DIAL]. ± Program different frequencies in "11A" and "11B" re- spectively. ± Set other data (e.g. offset frequency, duplex direction, tone squelch, etc.), if desired. e Push and hold [S.MW](M/CALL) for 1 sec. to enter the se- lect memory write mode. • 1 short and 1 long beeps sound. • " " indication and memory channel number blink. r Rotate [DIAL] to select the desired programmed scan edge channel from 0A to 24A. t Push and hold [S.MW](M/CALL) for 1 sec. • 3 beeps sound. • The other scan edge channel "B," 0B to 24B, is automatically selected when continuing to push [S.MW](M/CALL) after programming. y To program a frequency for the other pair of scan edges, 0B to 24B, repeat steps w and r. • If the same frequency is programmed into a pair of scan edges, programmed scan will not function. [EXAMPLE]: Programming 145.300 MHz into scan edges 3A. [DIAL] Push and hold Rotate to select Push and hold for 1 sec. "3A." for 1 sec. Enter select memory write mode. "3A" is selected. Return to the VFO mode. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 105