Lenovo ThinkServer RD210 Hardware Maintenance Manual - Page 35

Table 3. DSA Preboot messages continued, Stress Test

Page 35 highlights

Table 3. DSA Preboot messages (continued) • Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. • See Chapter 9 "Parts listing, ThinkServer RD210 Type 3795, 3796, 3818, and 3819" on page 143 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). • If an action step is preceded by "(Trained service technician only)," that step must be performed only by a Trained service technician. • Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information, hints, tips, and new device drivers or to submit a request for information. Message number Component Test State Description Action 089-802-xxx CPU CPU Stress Test Aborted System resource availability error. 1. Turn off and restart the system. 2. Make sure that the DSA code is at the latest level. For the latest level of DSA code, go to :http://www.lenovo.com/support 3. Run the test again. 4. Make sure that the system firmware is at the latest level. The installed firmware level is shown in the DSA event log in the Firmware/VPD section for this component. For the latest level of firmware, go to:http://www.lenovo.com/support. 5. Run the test again. 6. Turn off and restart the system if necessary to recover from a hung state. 7. Run the test again. 8. Make sure that the system firmware is at the latest level. The installed firmware level is shown in the DSA event log in the Firmware/VPD section for this component. 9. Run the test again. 089-802-xxx CPU CPU Stress Test Aborted System resource availability error. 1. Replace the following components one at a time, in the order shown, and run this test again to determine whether the problem has been solved: a. (Trained service technician only) Microprocessor board b. (Trained service technician only) Microprocessor 2. If the failure remains, go to http://www.lenovo.com/support for more troubleshooting information. Chapter 5. Diagnostic 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182

Table 3. DSA Preboot messages (continued)
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
See Chapter 9 “Parts listing, ThinkServer RD210 Type 3795, 3796, 3818, and 3819” on page 143 to determine
which components are customer replaceable units (CRU) and which components are field replaceable
units (FRU).
If an action step is preceded by “(Trained service technician only),” that step must be performed only by
a Trained service technician.
Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Message
number
Component
Test
State
Description
Action
089-802-xxx
CPU
CPU
Stress Test
Aborted
System
resource
availability
error.
1.
Turn off and restart the system.
2.
Make sure that the DSA code is at the latest
level. For the latest level of DSA code, go to
3.
Run the test again.
4.
Make sure that the system firmware is
at the latest level. The installed firmware
level is shown in the DSA event log in the
Firmware/VPD section for this component.
For the latest level of firmware, go
5.
Run the test again.
6.
Turn off and restart the system if necessary to
recover from a hung state.
7.
Run the test again.
8.
Make sure that the system firmware is
at the latest level. The installed firmware
level is shown in the DSA event log in the
Firmware/VPD section for this component.
9.
Run the test again.
089-802-xxx
CPU
CPU
Stress Test
Aborted
System
resource
availability
error.
1.
Replace the following components one at a
time, in the order shown, and run this test
again to determine whether the problem has
been solved:
a.
(Trained service technician only)
Microprocessor board
b. (Trained service technician only)
Microprocessor
2.
If the failure remains, go to
more troubleshooting information.
Chapter 5
.
Diagnostic
27