Lenovo ThinkServer RD210 Hardware Maintenance Manual - Page 5

Contents, General Checkout - memory

Page 5 highlights

Contents Chapter 1. About this manual . . . . . 1 Important Safety Information 1 Important information about replacing RoHS compliant FRUs 1 Turkish statement of compliance 2 Chapter 2. Safety information . . . . . 3 Guidelines for trained service technicians . . . . . 4 Inspecting for unsafe conditions 4 Guidelines for servicing electrical equipment . . 4 Safety statements 5 Chapter 3. General information. . . . . 9 Introduction 9 Features and technologies 9 Specifications 11 Software 13 EasyStartup 13 EasyManage 13 Chapter 4. General Checkout. . . . . 15 Diagnosing a problem 15 Undocumented problems 17 Chapter 5. Diagnostic 19 Running the diagnostic programs 19 Diagnostic text messages 20 EasyLED 20 Remind button 21 EasyLED switch 21 EasyLED LEDs 21 Viewing the test log 25 Diagnostic messages 26 Automated boot recovery (ABR 60 Three boot failure 61 Chapter 6. Removing and replacing system components 63 Removing and installing the system battery . . . 63 Removing the system battery 63 Installing the system battery 64 Chapter 7. Installing optional devices and replacing customer replaceable units 67 Installation guidelines 67 System reliability guidelines 68 Working inside the server with the power on . 68 © Copyright Lenovo 2005, 2010 Handling static-sensitive devices . . . . . 68 System-board internal connectors 69 Major components of the server 70 Removing and replacing the cover 72 Removing the cover 72 Replacing the cover 73 Internal cable routing and connectors. . . . . . 73 Removing and installing the microprocessor 2 air baffle 76 Removing the microprocessor 2 air baffle . . 76 Installing the microprocessor 2 air baffle . . . 76 Removing and installing the DIMM air baffle . . . 77 Removing the DIMM air baffle 77 Installing the DIMM air baffle 77 Removing and installing a hot-swap hard disk drive 78 Removing a hot-swap hard disk drive . . . . 78 Installing a hot-swap hard disk drive . . . . 79 IDs for hot-swap hard disk drives . . . . . 80 Removing and installing a PCI riser-card assembly 81 Removing a PCI riser-card assembly . . . . 81 Installing a PCI riser card assembly . . . . . 82 Removing and installing an adapter 82 Removing an adapter 83 Installing an adapter 84 Removing and installing a memory module (DIMMs 85 Removing a memory module (DIMMs). . . . 85 Installing a memory module (DIMMs) . . . . 86 Removing and installing the IBM ServeRAID-BR10i SAS/SATA Controller 91 Removing the IBM ServeRAID-BR10i SAS/SATA Controller 91 Installing the IBM ServeRAID-BR10i SAS/SATA Controller 92 Removing and installing the optional IBM ServeRAID-MR10i SAS/SATA Controller. . . . . 94 Removing the optional IBM ServeRAID-MR10i SAS/SATA Controller 97 Installing the optional IBM ServeRAID-MR10i SAS/SATA Controller 97 Removing and installing a hot-swap power supply 97 Removing a hot-swap power supply . . . . 98 Installing a hot-swap power supply . . . . . 99 Removing and installing a hot-swap fan assembly 100 Removing a hot-swap fan assembly . . . . 100 v

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182

Contents
Chapter 1. About this manual
.....
1
Important Safety Information
.
.
.
.
.
.
.
.
.
.
1
Important information about replacing RoHS
compliant FRUs
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
1
Turkish statement of compliance
.
.
.
.
.
.
.
.
2
Chapter 2. Safety information
.....
3
Guidelines for trained service technicians
.
.
.
.
.
4
Inspecting for unsafe conditions
.
.
.
.
.
.
.
4
Guidelines for servicing electrical equipment .
.
4
Safety statements
.
.
.
.
.
.
.
.
.
.
.
.
.
.
5
Chapter 3. General information
.....
9
Introduction
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
9
Features and technologies
.
.
.
.
.
.
.
.
.
.
.
9
Specifications
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
11
Software
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
13
EasyStartup
.
.
.
.
.
.
.
.
.
.
.
.
.
.
13
EasyManage
.
.
.
.
.
.
.
.
.
.
.
.
.
.
13
Chapter 4. General Checkout
.....
15
Diagnosing a problem
.
.
.
.
.
.
.
.
.
.
.
.
15
Undocumented problems
.
.
.
.
.
.
.
.
.
.
17
Chapter 5. Diagnostic
.........
19
Running the diagnostic programs
.
.
.
.
.
.
.
19
Diagnostic text messages
.
.
.
.
.
.
.
.
.
.
20
EasyLED
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
20
Remind button
.
.
.
.
.
.
.
.
.
.
.
.
.
21
EasyLED switch
.
.
.
.
.
.
.
.
.
.
.
.
21
EasyLED LEDs
.
.
.
.
.
.
.
.
.
.
.
.
.
21
Viewing the test log
.
.
.
.
.
.
.
.
.
.
.
.
.
25
Diagnostic messages
.
.
.
.
.
.
.
.
.
.
.
.
26
Automated boot recovery (ABR)
.
.
.
.
.
.
.
.
60
Three boot failure
.
.
.
.
.
.
.
.
.
.
.
.
.
61
Chapter 6. Removing and replacing
system components
.........
63
Removing and installing the system battery
.
.
.
63
Removing the system battery
.
.
.
.
.
.
.
63
Installing the system battery
.
.
.
.
.
.
.
64
Chapter 7. Installing optional devices
and replacing customer replaceable
units
..................
67
Installation guidelines
.
.
.
.
.
.
.
.
.
.
.
.
67
System reliability guidelines
.
.
.
.
.
.
.
.
68
Working inside the server with the power on
.
68
Handling static-sensitive devices
.
.
.
.
.
68
System-board internal connectors
.
.
.
.
.
.
.
69
Major components of the server
.
.
.
.
.
.
.
.
70
Removing and replacing the cover
.
.
.
.
.
.
.
72
Removing the cover
.
.
.
.
.
.
.
.
.
.
.
72
Replacing the cover
.
.
.
.
.
.
.
.
.
.
.
73
Internal cable routing and connectors
.
.
.
.
.
.
73
Removing and installing the microprocessor 2 air
baffle
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
76
Removing the microprocessor 2 air baffle
.
.
76
Installing the microprocessor 2 air baffle .
.
.
76
Removing and installing the DIMM air baffle .
.
.
77
Removing the DIMM air baffle
.
.
.
.
.
.
.
77
Installing the DIMM air baffle
.
.
.
.
.
.
.
77
Removing and installing a hot-swap hard disk
drive
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
78
Removing a hot-swap hard disk drive
.
.
.
.
78
Installing a hot-swap hard disk drive
.
.
.
.
79
IDs for hot-swap hard disk drives
.
.
.
.
.
80
Removing and installing a PCI riser-card
assembly
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
81
Removing a PCI riser-card assembly
.
.
.
.
81
Installing a PCI riser card assembly
.
.
.
.
.
82
Removing and installing an adapter
.
.
.
.
.
.
82
Removing an adapter
.
.
.
.
.
.
.
.
.
.
83
Installing an adapter
.
.
.
.
.
.
.
.
.
.
.
84
Removing and installing a memory module
(DIMMs)
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
85
Removing a memory module (DIMMs)
.
.
.
.
85
Installing a memory module (DIMMs)
.
.
.
.
86
Removing and installing the IBM ServeRAID-BR10i
SAS/SATA Controller
.
.
.
.
.
.
.
.
.
.
.
.
91
Removing the IBM ServeRAID-BR10i
SAS/SATA Controller
.
.
.
.
.
.
.
.
.
.
91
Installing the IBM ServeRAID-BR10i SAS/SATA
Controller
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
92
Removing and installing the optional IBM
ServeRAID-MR10i SAS/SATA Controller
.
.
.
.
.
94
Removing the optional IBM ServeRAID-MR10i
SAS/SATA Controller
.
.
.
.
.
.
.
.
.
.
97
Installing the optional IBM ServeRAID-MR10i
SAS/SATA Controller
.
.
.
.
.
.
.
.
.
.
97
Removing and installing a hot-swap power
supply
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
97
Removing a hot-swap power supply
.
.
.
.
98
Installing a hot-swap power supply
.
.
.
.
.
99
Removing and installing a hot-swap fan
assembly
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
100
Removing a hot-swap fan assembly
.
.
.
.
100
© Copyright Lenovo 2005, 2010
v