Lenovo ThinkServer RD210 Hardware Maintenance Manual - Page 57
Run the test again., the latest level. The installed firmware
View all Lenovo ThinkServer RD210 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 57 highlights
Table 3. DSA Preboot messages (continued) • Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. • See Chapter 9 "Parts listing, ThinkServer RD210 Type 3795, 3796, 3818, and 3819" on page 143 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). • If an action step is preceded by "(Trained service technician only)," that step must be performed only by a Trained service technician. • Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information, hints, tips, and new device drivers or to submit a request for information. Message number Component Test State Description Action 201-808-xxx Memory Memory Test Aborted Test canceled: memory controller display/alter buffer execute error. 1. Turn off and restart the system. 2. Run the test again. 3. Make sure that the server firmware is at the latest level. The installed firmware level is shown in the DSA event log in the Firmware/VPD section for this component. 4. Run the test again. 5. If the failure remains, go to http://www.lenovo.com/support for more troubleshooting information. 201-809-xxx Memory Memory Test Aborted Test canceled program error: operation running fast scrub. 1. Turn off and restart the system. 2. Run the test again. 3. Make sure that the DSA code is at the latest level. For the latest level of DSA code, go to: http://www.lenovo.com/support 4. Make sure that the server firmware is at the latest level. The installed firmware level is shown in the DSA event log in the Firmware/VPD section for this component. 5. Run the test again. 6. If the failure remains, go to http://www.lenovo.com/support for more troubleshooting information. 201-810-xxx Memory Memory Test Aborted Test 1. Turn off and restart the system. stopped: unknown error code xxx received in 2. Run the test again. 3. Make sure that the DSA code is at the latest level. For the latest level of DSA code, go to: http://www.lenovo.com/support COMMONEXIT4. Make sure that the server firmware is at procedure. the latest level. The installed firmware level is shown in the DSA event log in the Firmware/VPD section for this component. 5. Run the test again. 6. If the failure remains, go to http://www.lenovo.com/support for more troubleshooting information. Chapter 5. Diagnostic 49