Ricoh AP3800C Maintenance Guide - Page 16
Replacing the Fuser Oil Unit, Replace Fuser, Oil Unit TypeG
View all Ricoh AP3800C manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
Replacing Consumables and Maintenance Kit Replacing the Fuser Oil Unit R CAUTION: D If the External Tray is attached to 1 • The Fusing Unit becomes very the printer, raise it in the direc- hot. When installing the new tion of the arrow (A), and remove Fuser Oil Unit, turn off the printer it (B). and wait about an hour. After that, install the new Fusing Unit. Not waiting for the unit to cool down can result in a burn. If "Replace Fuser Oil Unit (TypeG)" appears on the panel display, replace the Fuser Oil Unit. Replace Fuser Oil Unit (TypeG) A Turn off the power switch and unplug the power cable. Important ❒ Be sure to wait about an hour to prevent a burn. B If 2 Tray Finisher is installed, de- tach it from the printer. Reference See p.1 "Detaching the SR770 (2 Tray Finisher)" C If the Duplex Unit is installed, open the Duplex Reversal Unit. Reference See p.2 "Opening and Closing the Duplex Reversal Unit" ZDJP038J E Pull out the left cover of the print- er slowly. ZDJH047J F Open the upper left cover. ZDJH048J 6