Ricoh AP3800C Maintenance Guide - Page 20
Replacing the Photoconductor Unit, Replace Black, PCU Type F, Replace Color
View all Ricoh AP3800C manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
Replacing Consumables and Maintenance Kit Replacing the Photoconductor Unit 1 If "Replace Black PCU (Type F)" appears on the panel display, replace the black Photoconductor Unit. C Take out the green screwdriver. Use this screwdriver for all attach- ment and detachment of screws. Replace Black PCU (Type F) If "Replace Color PCU (Type A)" appears on the panel display, replace the three color Photoconductor Units. Replace Color PCU (Type A) A Turn off the power switch and unplug the power cable. B Open the front cover slowly by pulling down from the two areas on the left and right. ZDJH013J D Turn the light brown lever coun- terclockwise. ZDJH014E E Loosen two screws that are fasten- ZDJH007J ing the inner cover using provid- ed screwdriver. ZDJH015J You cannot remove these two screws. 10