Sennheiser ADN D1 Instructions for Use - Page 19

>35 V, Large conference system with redundant ring topology

Page 19 highlights

Structuring and controlling the conference system Large conference system with redundant ring topology The redundant ring topology ensures that, should one conference unit or system cable fail or be manipulated, all other conference units of the cable ring will continue to function reliably. For setting up a large conference system with redundant ring topology, you require one ADN CU1 central unit for controlling the conference and additional ADN PS power supplies for powering the conference units. The conference units are interconnected in rings and two rings can be connected to each ADN PS power supply. ADN CU1 ADN PS (max. 15) PORT I/II PORT I 1 PORT I 2 PORT II 2 PORT II 1 max. 40 ADN D1/ADN C1 ADN CU1 ADN PS max. 80 m 1 2 3 max. 80 m ca. 2-5 m ca. 2-5 m 52.8 V ... 20 >35 V When connecting the conference units to an ADN PS power supply, you can mix different cable topologies (simple cabling with cable strings or redundant ring topology) as long as you ensure correct cabling and comply with the specifications (see page 32 and page 34). 18 | ADN Digital Conference System

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169

Structuring and controlling the conference system
18 |
ADN Digital Conference System
Large conference system with redundant ring topology
The redundant ring topology ensures that, should one conference unit or system
cable fail or be manipulated, all other conference units of the cable ring will con-
tinue to function reliably.
For setting up a large conference system with redundant ring topology, you require
one ADN CU1 central unit for controlling the conference and additional ADN PS
power supplies for powering the conference units. The conference units are inter-
connected in rings and two rings can be connected to each ADN PS power supply.
When connecting the conference units to an ADN PS power supply, you can
mix different cable topologies (simple cabling with cable strings or redun-
dant ring topology) as long as you ensure correct cabling and comply with
the specifications (see page 32 and page 34).
PORT I/II
ADN PS
(max. 15)
ADN CU1
max. 80 m
ca. 2-5 m
52.8 V
>35 V
20
1
5
2
3
...
max. 80 m
ADN CU1
ADN PS
ca. 2-5 m
max. 40
ADN D1/ADN C1
PORT I
2
PORT I
1
PORT II
1
PORT II
2