Sennheiser ADN D1 Instructions for Use - Page 66

Display, Meaning and causes, Meaning, Displaying the temperature status, Temperature, System

Page 66 highlights

Configuring the conference system via the central unit Display V V -- P P -- Meaning and causes An undervoltage can be caused by • faulty conference units • too long system cables • too many conference units connected to a PORT socket The PORT socket is deactivated due to e.g. • no conference units connected • a short-circuit The power of the ADN CU1 central unit or ADN PS power supply is not sufficient because too many conference units are connected. Information on the power output of the ADN CU1 central unit or ADN PS power supply is not yet available. If an error icon appears (see page 59), check your conference system for the errors mentioned above. If an error is detected at startup of the central unit, first eliminate the error and then perform a manual self-test (see page 67) to check if the error still persists. If an error has only occured during operation and has already been eliminated, this is automatically detected by the central unit. Possible steps for error elimination: • Eliminate the errors separately for the ADN CU1 central unit, the ADN PS power supplies and the respective affected PORT sockets. • Calculate the maximum length of the cable string or cable ring (see page 15) and, if necessary, reduce the cable length. • Reduce the number of conference units to 15-20 max. per cable string. • If necessary, further reduce the number of conference units until there are no errors reported. Then add conference units one after the other and observe the central unit's display panel. If an error is reported, the cause of the error might be the last added conference unit, the cable used or metal parts that bridge the contacts of the plug connection. Displaying the temperature status - "Temperature" Main Menu System Menu Diagnostics Select and call up the "Diagnostics" submenu Diagnostics System Load Temperature Bus Statistics No Select and call up the "Temperature" menu item Temperature System : ☺ No View the information; exit the menu item Temperature System : CU : PS07 : If the temperature of the ADN CU1 central unit and of the ADN PS power supplies is within the normal range, the ☺ icon appears behind "System". If the temperature of the ADN CU1 central unit and the ADN PS power supplies exceeds the limit values, the icon appears behind "System" and the affected components are listed together with the icon below "System". No Examples for the listing of affected components: Display CU PS07 Meaning ADN CU1 central unit ADN PS power supply connected to the central unit at the seventh position ADN Digital Conference System | 65

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169

ADN Digital Conference System
| 65
Configuring the conference system via the central unit
If an error icon appears (see page 59), check your conference system for the errors
mentioned above.
Possible steps for error elimination:
Eliminate the errors separately for the ADN CU1 central unit, the ADN PS power
supplies and the respective affected PORT sockets.
Calculate the maximum length of the cable string or cable ring (see page 15)
and, if necessary, reduce the cable length.
Reduce the number of conference units to 15-20 max. per cable string.
If necessary, further reduce the number of conference units until there are no
errors reported.
Then add conference units one after the other and observe the central unit’s
display panel. If an error is reported, the cause of the error might be the last
added conference unit, the cable used or metal parts that bridge the contacts
of the plug connection.
Displaying the temperature status –
“Temperature”
If the temperature of the ADN CU1 central unit and of the ADN PS power supplies
is within the normal range, the
icon appears behind “
System
”.
If the temperature of the ADN CU1 central unit and the ADN PS power supplies
exceeds the limit values, the
icon appears behind “
System
” and the affected
components are listed together with the
icon below “
System
”.
Examples for the listing of affected components:
V
An undervoltage can be caused by
faulty conference units
too long system cables
too many conference units connected to a PORT socket
V
--
The PORT socket is deactivated due to e.g.
no conference units connected
a short-circuit
P
The power of the ADN CU1 central unit or ADN PS power supply is
not sufficient because too many conference units are connected.
P
--
Information on the power output of the ADN CU1 central unit or
ADN PS power supply is not yet available.
If an error is detected
at startup
of the central unit, first eliminate the error
and then perform a manual
self-test
(see page 67) to check if the error still
persists.
If an error has only occured
during operation
and has already been elimi-
nated, this is automatically detected by the central unit.
Display
Meaning and causes
/
/
Select and call up the
“Diagnostics” submenu
Select and call up the
“Temperature” menu
item
View the information;
exit the menu item
Diagnostics
System Load
Temperature
Bus Statistics
Temperature
No
No
Main Menu
System Menu
Diagnostics
System
:
Temperature
No
System
:
±
CU
:
±
PS07
:
±
/
/
Display
Meaning
CU
ADN CU1 central unit
PS07
ADN PS power supply connected to the central unit at the seventh
position