Sony DVWM2000 Product Manual (Operation Manual 1st Edition (Revised 6)) - Page 130

Item number, Settings, In 525-line mode, To set the ID code, TC&UB, TCG REGEN MODE

Page 130 highlights

Chapter 12 Setup Menus 12-4 Items in the Extended Setup Menu Menu items in the range 600 to 650, relating to the time code generator Item number Item name Settings 601 VITC POSITION SEL-1 In 525-line mode Select a line to insert the VITC in. 12H ... 16H ... 20H: Select any line from 12 to 20. Note You can insert the VITC signal in two places. To insert it in two places, set both items 601 and 602. In 625-line mode Select a line to insert the VITC in. 9H ... 19H ... 22H: Select any line from 9 to 22. Note You can insert the VITC signal in two places. To insert it in two places, set both items 601 and 602. 602 VITC POSITION SEL-2 In 525-line mode Select a line to insert the VITC in. 12H ... 18H ... 20H: Select any line from 12 to 20. Note You can insert the VITC signal in two places. To insert it in two places, set both items 601 and 602. In 625-line mode Select a line to insert the VITC in. 9H ... 21H ... 22H: Select any line from 9 to 22. Note You can insert the VITC signal in two places. To insert it in two places, set both items 601 and 602. 603 ID CODE PRESET Select whether or not to set the ID code. OFF : Do not set the ID code. ON: Set the ID code. To set the ID code: Press the F5 (SET) button with this menu item displayed in the menu display, to enter the ID code setting mode. You can then set the user ID digit by digit using the T and t buttons for digit selection. When all required digits have been set correctly, press the F5 (SET) button again to save the ID code and exit from the ID code setting mode. 604 ID CODE SW Select whether or not to record the ID code set using item 603 in the user bits. OFF : Record the normal data in the user bits. ON: Record the ID code in the user bits. 605 TCG REGEN MODE Select the signals to be regenerated when the time code generator is in the regeneration mode (i.e., when the function menu item TCG (F2) is set to REGEN). TC&UB : Both the time code and user bit signals are regenerated. TC: Only the time code signal is regenerated. UB: Only the user bit signal is regenerated. (Continued) 12-16 Chapter 12 Setup Menus

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164

12-4
Items in the Extended Setup Menu
Chapter 12
Setup Menus
12-16
Chapter 12
Setup Menus
Menu items in the range 600 to 650, relating to the time code generator
Item number
601
602
603
604
605
Item name
VITC POSITION SEL-1
VITC POSITION SEL-2
ID CODE PRESET
ID CODE SW
TCG REGEN MODE
Settings
In 525-line mode
Select a line to insert the VITC in.
12H ... 16H ... 20H:
Select any line from 12 to 20.
Note
You can insert the VITC signal in two places. To insert it in two places, set both
items 601 and 602.
In 625-line mode
Select a line to insert the VITC in.
9H ... 19H ... 22H:
Select any line from 9 to 22.
Note
You can insert the VITC signal in two places. To insert it in two places, set both
items 601 and 602.
In 525-line mode
Select a line to insert the VITC in.
12H ... 18H ... 20H:
Select any line from 12 to 20.
Note
You can insert the VITC signal in two places. To insert it in two places, set both
items 601 and 602.
In 625-line mode
Select a line to insert the VITC in.
9H ... 21H ... 22H:
Select any line from 9 to 22.
Note
You can insert the VITC signal in two places. To insert it in two places, set both
items 601 and 602.
Select whether or not to set the ID code.
OFF :
Do not set the ID code.
ON:
Set the ID code.
To set the ID code:
Press the F5 (SET) button with this menu item displayed in the menu display, to
enter the ID code setting mode. You can then set the user ID digit by digit using
the
T
and
t
buttons for digit selection. When all required digits have been set
correctly, press the F5 (SET) button again to save the ID code and exit from the
ID code setting mode.
Select whether or not to record the ID code set using item 603 in the user bits.
OFF :
Record the normal data in the user bits.
ON:
Record the ID code in the user bits.
Select the signals to be regenerated when the time code generator is in the
regeneration mode (i.e., when the function menu item TCG (F2) is set to
REGEN).
TC&UB :
Both the time code and user bit signals are regenerated.
TC:
Only the time code signal is regenerated.
UB:
Only the user bit signal is regenerated.
(Continued)