Dell PowerEdge C6100 Hardware Owner's Manual - Page 23
POST Error Codes, Collecting System Event Log for Investigation - bios
View all Dell PowerEdge C6100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
POST Error Codes Collecting System Event Log for Investigation Error Messages are logged in the System Event Log (SEL). The SEL can be accessed through system BIOS and the BMC setup for investigation. You can also access SEL by browsing to the IP address of the BMC. Code Log in BMC Cause Corrective Actions 0000h Yes Timer Count Read/Write Error Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 143. 0003h Yes CMOS Battery Error See "Troubleshooting the System Battery" on page 118. 0004h Yes CMOS Diagnostic Status Error Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 143. 0005h Yes CMOS Checksum Error Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 143. 000Bh Yes CMOS Memory Size Error Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 143. About Your System 23