Dell PowerEdge C6100 Hardware Owner's Manual - Page 32
h No, 8400h Yes, BIOS Update BMC FRU failed
View all Dell PowerEdge C6100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
Code Log in BMC Cause Corrective Actions 8301h No SMBIOS Not Enough Space In See "Troubleshooting F000 System Memory" on page 121. If the problem persists, see "Getting Help" on page 143. 8302h No SMBIOS Not Enough Space In See "Troubleshooting F000 System Memory" on page 121. If the problem persists, see "Getting Help" on page 143. 8400h Yes Redirect Memory Error See "Troubleshooting System Memory" on page 121. If the problem persists, see "Getting Help" on page 143. F001h No System Event Log Full Check the SEL for details on the events, then clear the SEL. F002h No BMC FRU Header checksum bad Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 143. F003h No BIOS Update BMC FRU failed Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 143. F004h No BMC FRU Internal Area checksum bad Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 143. 32 About Your System