Code Log in BMC Cause Corrective Actions 0047h Yes PMM Memory Allocation Error See "Troubleshooting System Memory" on page 121. If the problem persists, see "Getting Help" on page 143. 0048h Yes Password Check Error Reset password. See "Jumper Settings" on page 139. If the problem persists, see "Getting Help" on page 143. 004Ah Yes ADM Module Error See "Getting Help" on page 143. 004Bh Yes Language Module Error See "Getting Help" on page 143. 005Dh Yes ATA SMART Feature Error See "Getting Help" on page 143. 005Eh Yes Non-Critical Password Check Error Reset password. See "Jumper Settings" on page 139. If the problem persists, see "Getting Help" on page 143. 0060h Yes HDD 0 Error See "Troubleshooting a Hard Drive" on page 123. 0061h Yes HDD 1 Error See "Troubleshooting a Hard Drive" on page 123. 0062h Yes HDD 2 Error See "Troubleshooting a Hard Drive" on page 123. 0063h Yes HDD 3 Error See "Troubleshooting a Hard Drive" on page 123. 0064h Yes HDD 4 Error See "Troubleshooting a Hard Drive" on page 123. 0065h Yes HDD 5 Error See "Troubleshooting a Hard Drive" on page 123. About Your System 25