Cisco WS-C2960S-24PD-L Software Guide - Page 307

GBIC_1000BASET Messages

Page 307 highlights

Appendix A System Messages Error Message and Recovery Procedures Error Message FRANK-3-VLAN_DESC_EXCEEDED: Out of vlan desc!!\n Explanation There are no unused VLAN descriptors left in the VLAN descriptor table for that VLAN ID. Recommended Action Copy the error message exactly as it appears on the console or in the system log. Enter the show tech-support command to gather data that might provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, contact your Cisco technical support representative, and provide the representative with the gathered information. Error Message FRANK-6-MODULE_INSERTED: Module in slot [dec] is inserted Explanation A Gigabit Ethernet controller-based module has been hot-inserted in a slot. Recommended Action No action is required. Error Message FRANK-6-MODULE_REMOVED: Module in slot [dec] was removed Explanation The module has been removed from the slot. Recommended Action No action is required. GBIC_1000BASET Messages This section contains the 1000BASE-T Cisco Gigabit Interface Converter (GBIC) error messages. Error Message GBIC_1000BASET-6-GBIC_1000BASET_DEFAULT_CONFIG: 1000-BaseT GBIC module is detected in [chars]. Speed and duplex will be autonegotiated Explanation 1000-BaseT GBIC modules only support autonegotiation on speed and duplex. Recommended Action No action is required. Error Message GBIC_1000BASET-6-GBIC_1000BASET_NO_CONFIG_DUPLEX: Configuration ignored. 1000-BaseT GBIC modules only support autonegotiation on duplex. Explanation 1000-BaseT GBIC modules only support autonegotiation on duplex. Recommended Action No action is required. Error Message GBIC_1000BASET-6-GBIC_1000BASET_NO_CONFIG_NEGOTIATE: Configuration ignored. 1000-BaseT GBIC modules only support autonegotiation. Explanation 1000-BaseT GBIC modules only support autonegotiation. Recommended Action No action is required. 78-6511-08 Catalyst 2900 Series XL and Catalyst 3500 Series XL Software Configuration Guide A-15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305
  • 306
  • 307
  • 308
  • 309
  • 310
  • 311
  • 312
  • 313
  • 314
  • 315
  • 316
  • 317
  • 318
  • 319
  • 320
  • 321
  • 322
  • 323
  • 324
  • 325
  • 326
  • 327
  • 328
  • 329
  • 330
  • 331
  • 332
  • 333
  • 334
  • 335
  • 336
  • 337
  • 338
  • 339
  • 340
  • 341
  • 342
  • 343
  • 344
  • 345
  • 346
  • 347
  • 348
  • 349
  • 350
  • 351
  • 352
  • 353
  • 354
  • 355
  • 356
  • 357
  • 358
  • 359
  • 360
  • 361
  • 362
  • 363
  • 364
  • 365
  • 366
  • 367
  • 368

A-15
Catalyst 2900 Series XL and Catalyst 3500 Series XL Software Configuration Guide
78-6511-08
Appendix A
System Messages
Error Message and Recovery Procedures
Error Message
FRANK-3-VLAN_DESC_EXCEEDED: Out of vlan desc!!\n
Explanation
There are no unused VLAN descriptors left in the VLAN descriptor table for that VLAN
ID.
Recommended Action
Copy the error message exactly as it appears on the console or in the system log.
Enter the
show tech-support
command to gather data that might provide information to determine
the nature of the error. If you cannot determine the nature of the error from the error message text or
from the
show tech-support
output, contact your Cisco technical support representative, and provide
the representative with the gathered information.
Error Message
FRANK-6-MODULE_INSERTED: Module in slot [dec] is inserted
Explanation
A Gigabit Ethernet controller-based module has been hot-inserted in a slot.
Recommended Action
No action is required.
Error Message
FRANK-6-MODULE_REMOVED: Module in slot [dec] was removed
Explanation
The module has been removed from the slot.
Recommended Action
No action is required.
GBIC_1000BASET Messages
This section contains the 1000BASE-T Cisco Gigabit Interface Converter (GBIC) error messages.
Error Message
GBIC_1000BASET-6-GBIC_1000BASET_DEFAULT_CONFIG: 1000-BaseT GBIC
module is detected in [chars]. Speed and duplex will be autonegotiated
Explanation
1000-BaseT GBIC modules only support autonegotiation on speed and duplex.
Recommended Action
No action is required.
Error Message
GBIC_1000BASET-6-GBIC_1000BASET_NO_CONFIG_DUPLEX: Configuration
ignored. 1000-BaseT GBIC modules only support autonegotiation on duplex.
Explanation
1000-BaseT GBIC modules only support autonegotiation on duplex.
Recommended Action
No action is required.
Error Message
GBIC_1000BASET-6-GBIC_1000BASET_NO_CONFIG_NEGOTIATE: Configuration
ignored. 1000-BaseT GBIC modules only support autonegotiation.
Explanation
1000-BaseT GBIC modules only support autonegotiation.
Recommended Action
No action is required.