U.S. and Canada, Japan, a NEMA 5-15P 15 A, 125 V or NEMA 6-15P 15

Page 197 highlights

2. The appliance coupler (that is, the connector to the device itself, not the wall plug) must have a configuration for mating with a EN60 320 appliance inlet (Standard Sheet C14). 3. The length of the cord set must be as follows: t Minimum: 6.50 ft (2.0 m) t Maximum: 9.75 ft (3.0 m) U.S. and Canada 1. The cord set must be UL-Listed and CSA-Certified. 2. The minimum specifications for the flexible cord are: t No. 18 AWG t Type SJ t 3-conductor 3. The cord set must have a rated current capacity of at least 10 A. 4. The attachment plug must be an earth-grounding type with a NEMA 5-15P (15 A, 125 V) or NEMA 6-15P (15 A, 250 V) configuration. Japan 1. All components of the cord set (cord, connector, and plug) must bear a "T" mark and registration number in accordance with the Japanese Dentori Law. 2. The minimum specifications for the flexible cord are: t 0.75 mm2 conductors t Type VCT or VCTF t 3-conductor 3. The cord set must have a minimum rated current capacity of 7 A. 4. The attachment plug must be a two-pole, grounded type with a Japanese Industrial Standard C8303 (15 A, 125 VAC) configuration. Reference Guide A-7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234

Reference Guide
A-7
2. The appliance coupler (that is, the connector to the device
itself, not the wall plug) must have a configuration for
mating with a EN60 320 appliance inlet (Standard Sheet
C14).
3. The length of the cord set must be as follows:
Minimum:
6.50 ft (2.0 m)
Maximum:
9.75 ft (3.0 m)
U.S. and Canada
1. The cord set must be UL-Listed and CSA-Certified.
2. The minimum specifications for the flexible cord are:
No. 18 AWG
Type SJ
3-conductor
3.
The cord set must have a rated current capacity of at least
10 A.
4. The attachment plug must be an earth-grounding type with
a NEMA 5-15P (15 A, 125 V) or NEMA 6-15P (15 A,
250 V) configuration.
Japan
1. All components of the cord set (cord, connector, and plug)
must bear a “T” mark and registration number in
accordance with the Japanese Dentori Law.
2. The minimum specifications for the flexible cord are:
0.75 mm
2
conductors
Type VCT or VCTF
3-conductor
3. The cord set must have a minimum rated current capacity
of 7 A.
4. The attachment plug must be a two-pole, grounded type
with a Japanese Industrial Standard C8303 (15 A,
125 VAC) configuration.