Message, Description, Recommended Action, Check the Disable Code field. Run ACU
UPC - 720591250300
View all Compaq ML530R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 100 highlights
3-40 Compaq ProLiant ML530 Servers Maintenance and Service Guide Table 3-20 ADU Diagnostic Messages continued Message Description Accelerator status: Excessive ECC errors detected in at least one cache line. As a result, at least one cache line is no longer in use. At least one line in the cache is no longer in use due to excessive ECC errors detected during use of the memory associated with that cache line. Accelerator status: Excessive ECC errors detected in multiple cache lines. As a result, the cache is no longer in use. The number of cache lines experiencing excessive error checking and correcting (ECC) errors has reached a preset limit. The cache has been shut down. Accelerator status: Obsolete data detected. During reset initialization, obsolete data was found in cache. This was due to drives being moved and written to by another controller. Accelerator status: Obsolete data was discarded. During reset initialization, obsolete data was found in cache and was discarded (not written to drives). Accelerator status: Obsolete data was flushed (written) to drives. During reset initialization, obsolete data was found in cache. Obsolete data was written to the drives, but newer data may have been overwritten. Accelerator status: Permanently disabled Array accelerator board has been permanently disabled. It remains disabled until it is reinitialized using the Array Configuration Utility (ACU). Accelerator status: Possible data loss in cache Possible data loss detected during power-up due to all batteries being below sufficient voltage level and no presence of identification signatures on the array accelerator board. Accelerator status: Temporarily disabled Array accelerator board has been temporarily disabled. Accelerator status: Unrecognized status A status was returned from the array accelerator board that ADU does not recognize. Recommended Action Replace the cache. If cache replacement is not done, the remaining cache lines should continue to operate properly. First, try reseating the cache to the controller. If that doesn't work, replace the cache. Normal operations should continue. The controller will either write data to the drives or discard the data completely. Normal operations should continue. If newer data was overwritten, you may need to restore newer data; otherwise, normal operations should continue. Check the Disable Code field. Run ACU to reinitialize the array accelerator board. There is no way to determine if dirty or bad data was in the cache and is now lost. Check the Disable Code field. Obtain the latest version of ADU. continued