Compaq ML530R Service Guide - Page 159
SCSI Port X drive ID Y firmware, SCSI Port X Drive ID X
UPC - 720591250300
View all Compaq ML530R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 159 highlights
6 Compaq ProLiant ML530 Servers Maintenance and Service Guide is failed 3-43 is undergoing drive recovery 3-43 needs replacing 3-43 upload code not readable 3-43 was inadvertently replaced 3-43 Drive Monitoring features are unobtainable 3-43 Drive Monitoring is NOT enabled 3-43 Drive time-out occurred on physical drive bay X 3-43 Drive X indicates position Y 3-43 Duplicate write memory error 3-43 Error occurred reading RIS copy from SCSI Port X 3-44 Fatal ROM Error 3-8 FYI, Drive (bay) X is non-Compaq supplied 3-44 Identify controller data did not match NVRAM 3-44 Identify logical drive data did not match NVRAM 3-44 Incorrect Drive Replaced 3-21 Insufficient adapter resources 3-44 Less than 75% batteries at sufficient voltage 3-44 Logical drive X failed due to cache error 3-44 Logical drive X status Failed 3-45 Interim Recovery 3-45 Loose Cable Detected 3-45 Needs Recover 3-45 Overheated 3-45 Overheating 3-45 Recovering 3-45 Wrong Drive Replaced 3-45 Loose cable detected, logical drives may be marked FAILED 3-46 Mirror data miscompare 3-46 No configuration for accelerator board 3-46 NVRAM configuration present, controller not detected 3-46 Permanently disabled 3-40 RESUME - F1 key 3-23 RIS copies between drives do not match 3-47 Run System Configuration Utility 3-23 SCSI Port X Drive ID X failed - Replace 3-48 firmware needs upgrading 3-48 has exceeded threshold(s) 3-47 has loose cable 3-48 is not stamped for monitoring 3-48 replaced on a good volume 3-48 RIS copy mismatch 3-48 SCSI Port X drive ID Y firmware needs upgrading 3-48 Set configuration command issued 3-48 Soft Firmware Upgrade required 3-48 Unable to communicate with drive on SCSI Port X 3-49 Unknown disable code 3-49 Unrecoverable read error 3-49 Unsupported Processor Detected System Halted 3-8 Warning bit detected 3-50 Warning, Drive Write Cache enabled on X 3-49 Write memory error 3-50 Wrong Accelerator 3-50 ESD See electrostatic discharge Event List printing 3-52 viewing 3-51 event messages, defined 3-53 event type ASR-2, system lockup 3-54 fan failure 3-53 machine environment Fan Inserted 3-53 Fan Removed 3-53 Fans Not Redundant 3-53 Overheat Condition 3-53 main memory Correctable Error threshold exceeded 3-53 Uncorrectable Error 3-53 operating system automatic OS shutdown 3-54 system crash 3-54 PCI bus error 3-53 power subsystem AC voltage problem 3-54 power AC overload 3-54