–1799, Hard Drive Test Error Codes, Table 3-12
UPC - 720591250300
View all Compaq ML530R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 92 highlights
3-32 Compaq ProLiant ML530 Servers Maintenance and Service Guide 1700-1799, Hard Drive Test Error Codes The 1700 series of diagnostic error codes identifies failures with hard drives, hard drive controller boards, hard drive cabling, and system board functions. If the system uses a drive array controller, see the "Array Diagnostic Utility (ADU)" section. Table 3-12 Hard Drive Test Error Codes Error Code Description 1700-xx Hard drive ID drive types test failed. 1701-xx Hard drive format test failed. 1702-xx Hard drive read test failed. 1703-xx Hard drive write/ read/ compare test failed. 1704-xx Hard drive random seek test failed. 1705-xx Hard drive controller test failed. 1708-xx Hard drive format bad track test failed. 1709-xx Hard drive reset controller test failed. 1710-xx Hard drive park head test failed. 1715-xx Hard drive head select test failed. 1716-xx Hard drive conditional format test failed. 1717-xx Hard drive ECC* test failed. 1719-xx Hard drive power mode test failed. 1736-xx Drive Monitoring failed. 1799-xx Invalid hard drive type failed. * Error Checking and Correcting Recommended Action 1. Run the System Configuration Utility and verify the drive type. 2. Replace the hard drive signal and power cables and retest. 3. Replace the hard drive controller and retest. 4. Replace the hard drive and retest. 5. Replace the system board and retest.