Compaq ML530R Service Guide - Page 72

Error Code, Audible Beeps, Probable Source of Problem, Recommended Action, do not, Internal SCSI cable - ml530 press f1 to continue

Page 72 highlights

3-12 Compaq ProLiant ML530 Servers Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps 1622-Internal SCSI None Jumper Board Not Installed 1703-SCSI cable None error detected. Terminated cable attached to output connector of SCSI backplane. System halted. 1703-SCSI cable None error detected. Must be configured for single backplane, simplex, or duplex. System halted. 1703-SCSI cable None error detected. Internal SCSI cable not attached to system board connector. System halted. 1720-Slot X Drive None Array - SMART Drive Detects Imminent Failure SCSI: Port Y: SCSI ID X Probable Source of Problem The system has detected that the array enabler board is not installed. A terminated cable is attached to the output connector of the SCSI backplane. Recommended Action Install the array enabler board. Remove terminated connector. Cables connected in unsupported configuration. Reconnect cables in a supported configuration as described in documentation. Incorrect cabling Ensure that the integrated SCSI controller has SCSI termination attached. Indicated drive has reported a SMART predictive-failure condition and may fail at some time in the future. If the drive is part of a nonfault-tolerant configuration, back up all data before replacing drive and restore all data afterward. If the drive is part of a fault-tolerant configuration do not replace the drive unless all other drives in the array are online. Press F1 to resume. continued

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168

3-12
Compaq ProLiant ML530 Servers Maintenance and Service Guide
Table 3-2
POST Error Messages
continued
Error Code
Audible Beeps
Probable Source of Problem
Recommended Action
1622-Internal SCSI
Jumper Board Not
Installed
None
The system has detected that the
array enabler board is not
installed.
Install the array enabler board.
1703-SCSI cable
error detected.
Terminated cable
attached to output
connector of SCSI
backplane. System
halted.
None
A terminated cable is attached to
the output connector of the SCSI
backplane.
Remove terminated connector.
1703-SCSI cable
error detected. Must
be configured for
single backplane,
simplex, or duplex.
System halted.
None
Cables connected in unsupported
configuration.
Reconnect cables in a
supported configuration as
described in documentation.
1703-SCSI cable
error detected.
Internal SCSI cable
not attached to
system board
connector. System
halted.
None
Incorrect cabling
Ensure that the integrated SCSI
controller has SCSI termination
attached.
1720-Slot
X
Drive
Array
SMART Drive
Detects Imminent
Failure SCSI: Port
Y
:
SCSI ID
X
None
Indicated drive has reported a
SMART predictive-failure
condition and may fail at some
time in the future.
If the drive is part of a
nonfault-tolerant configuration,
back up all data before
replacing drive and restore all
data afterward. If the drive is
part of a fault-tolerant
configuration
do not
replace the
drive unless all other drives in
the array are online. Press
F1
to
resume.
continued