Compaq ML530R Service Guide - Page 27
HotPlug System Fans - ml530 fan 5
UPC - 720591250300
View all Compaq ML530R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 27 highlights
2-12 Compaq ProLiant ML530 Servers Maintenance and Service Guide Hot-Plug System Fans Compaq ProLiant ML530 servers have two system fan baskets, one for the I/O fan and one for the CPU fan. Each basket can hold a primary and a redundant hot-plug system fan. The hot-plug system fans cool the system board components (I/O fan) and the processors (CPU fan). CAUTION: Never remove both fans from one system fan basket while the server is powered up. Overheating and damage to hardware could result. If the appropriate Compaq software drivers are installed, the operating system software will initiate a power shutdown in the event of overheating. To remove a hot-plug system fan: 1. Perform the preparation procedures. See "Hot-Pluggable Device" earlier in this chapter. 2. Remove the access panel. See "Access Panel" earlier in this chapter. 3. Press the locking latch in and lift the failed hot-plug system fan out of the system fan basket . 2 1 Figure 2-5. Removing a hot-plug system fan Reverse steps 1 through 3 to replace a hot-plug system fan with a new fan.