Compaq ML530R Service Guide - Page 110

messages. Run the System Configuration Utility, placed in a system that was

Page 110 highlights

3-50 Compaq ProLiant ML530 Servers Maintenance and Service Guide Table 3-20 ADU Diagnostic Messages continued Message Description Warning bit detected A monitor and performance threshold violation may have occurred. Status of a logical drive may not be OK. Write memory error Data could not be written to cache memory. This typically means that a parity error was detected while writing data to cache. This could be caused by incomplete connection between cache and controller. This is not a data loss circumstance. Wrong accelerator This could mean that either the board was replaced in the wrong slot or placed in a system that was previously configured with another board type. Included with this message is a message indicating the type of adapter sensed by ADU and a message indicating the type of adapter last configured in EISA nonvolatile RAM. Recommended Action Check the other error messages on the diagnosis screen for an indication of the problem. With power to system turned off, verify that the cache board is fully connected to controller. Check the diagnosis screen for other error messages. Run the System Configuration Utility to update the system configuration.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168

3-50
Compaq ProLiant ML530 Servers Maintenance and Service Guide
Table 3-20
ADU Diagnostic Messages
continued
Message
Description
Recommended Action
Warning bit
detected
A monitor and performance threshold
violation may have occurred. Status
of a logical drive may not be OK.
Check the other error messages on the
diagnosis screen for an indication of the
problem.
Write memory
error
Data could not be written to cache
memory. This typically means that a
parity error was detected while
writing data to cache. This could be
caused by incomplete connection
between cache and controller. This is
not a data loss circumstance.
With power to system turned off, verify that the
cache board is fully connected to controller.
Wrong
accelerator
This could mean that either the board
was replaced in the wrong slot or
placed in a system that was
previously configured with another
board type. Included with this
message is a message indicating the
type of adapter sensed by ADU and a
message indicating the type of
adapter last configured in EISA
nonvolatile RAM.
Check the diagnosis screen for other error
messages. Run the System Configuration Utility
to update the system configuration.