Compaq ML530R Service Guide - Page 74
Run the System Configuration, failed Set Block
UPC - 720591250300
View all Compaq ML530R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 74 highlights
3-14 Compaq ProLiant ML530 Servers Maintenance and Service Guide Table 3-2 POST Error Messages continued Error Code Audible Beeps 1729-Slot 1 Drive None Array - Disk Consistency Initialization in Progress - RAID 4/5 performance may be lower until auto-reliability monitoring has completed auto-background parity consistency initialization. 1730-Fixed Disk 0 None does not support DMA Mode. 1731-Fixed Disk 1 None does not support DMA Mode. 1740-Fixed Disk 0 None failed Set Block Mode command. 1741-Fixed Disk 1 None failed Set Block Mode command. 1750-Fixed Disk 0 None failed Identify command. 1751-Fixed Disk 1 None failed Identify command. 1760-Fixed Disk 0 None does not support Block Mode. 1761-Fixed Disk 1 None does not support Block Mode. Probable Source of Problem Initial RAID configuration in progress. Hard drive error Hard drive error Hard drive error Hard drive error Hard drive error Hard drive error Hard drive error Hard drive error Recommended Action Normal message following initialization, no action required. Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. continued