Compaq ML530R Service Guide - Page 149

Hot Plug Power Supply, 8 A at 200 VAC

Page 149 highlights

Physical and Operating Specifications 5-3 Hot-Plug Power Supply Table 5-2 Hot-Plug Power Supply Specifications International input specifications Nominal line voltage Range input line Frequency range Power factor Input current Inrush current (cold start) Holdup time U.S. input specifications Nominal line voltage Range input line Frequency range Power factor Input current Inrush current (cold start) Holdup time General specifications Full output rating Minimum load Ambient temperature range Operating Nonoperating Dielectric voltage withstand Input to output Input to ground Common and differential mode (superimposed on AC line) 200 to 240 VAC 180 to 270 VAC 47 to 63 Hz 0.95 3.8 A at 200 VAC

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168

Physical and Operating Specifications
5-3
Hot-Plug Power Supply
Table 5-2
Hot-Plug Power Supply Specifications
International input specifications
Nominal line voltage
200 to 240 VAC
Range input line
180 to 270 VAC
Frequency range
47 to 63 Hz
Power factor
0.95
Input current
3.8 A at 200 VAC
Inrush current (cold start)
<150 A at 132 VAC
Holdup time
20 ms from zero crossing at 240 VAC
U.S. input specifications
Nominal line voltage
100 to 120 VAC
Range input line
90 to 132 VAC
Frequency range
47 to 63 Hz
Power factor
0.95
Input current
7.6 A at 100 VAC
Inrush current (cold start)
<150 A at 132 VAC
Holdup time
20 ms from zero crossing at 120 VAC
General specifications
Full output rating
To 40
°
C and 1,524 m (To 104
°
F and 5,000 ft)
To 32
°
C and 3,048 m (To 90
°
F and 10,000 ft) derate
linearly
Minimum load
1.0 A on + 5 V output
1.0 A on +12 V output
0.5 A on +3.3 V output
Ambient temperature range
Operating
10
°
to 40
°
C (50
°
to 104
°
F)
Nonoperating
-40
°
to 65
°
C (-40
°
to 149
°
F)
Dielectric voltage withstand
Input to output
3000 VAC (minimum)
Input to ground
1500 VAC (minimum)
Common and differential mode
(superimposed on AC line)
2500V, 1
µ
s, damped sinusoid 600 V, 10
µ
s pulse 20%
step change in AC input voltage