D-Link DWC-2000-AP32-LIC User Manual - Page 156
Configure Flow-based Control
View all D-Link DWC-2000-AP32-LIC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 156 highlights
Section 5 - Advanced Network Configuration Configure Flow-based Control Path: Network > QoS > QoS Policy > Flow Control The Flow-Based QoS Policy allows you to limit the Bandwidth for a particular service. Changes here affect the traffic of a configured service that is egressed on the ports. 1. Go to Network > QoS > QoS Policy > Flow Control tab. 2. Click Add New Flow-based Control QoS. 3. Complete the fields in the table below and click Save. Field Profile Name Service Source IP Address Destination IP Address Bandwidth Description The name of the profile. Select the type of service you want to use. The choices are: Any, aim, bgp, bootp_client, bootp_server, cu-seeme udp, cu-seeme tcp, dns udp, dns tcp, finger, ftp, http, https, icmp, icq, imap2, imap3, irc, news, nfs, nntp, ping, pop3, pptp, rcmd, rea-audio, rexec, rlogin, rtelnet, rtsp tcp, rtsp udp, sftp, smtp, snmp tcp, snmp udp, snmp-traps tcp, snmp-traps udp, sql-net, ssh tcp, ssh udp, strmworks, tacacs, telnet, tftp, rip, kie, shttpd, ipsec-udp-encap, ident, vddolive, ssh, sip-tcp, sipudp, or icmpv6. The source IP address The destination IP address Limit the Bandwidth for a particular service. D-Link DWC-2000 User Manual 156