Alternatively, use the following command to display all component names: ASMCLI ‑list ‑components ‑showobjectid • Collection Operations - Specify a collection name. A collection name has the following format: Collection {ascii_string} For example: Collection{exchange_collection} • You can obtain the collection name from the ASM/ME GUI Collections node by browsing an individual collection's properties. Alternatively, use the following command to display of all Collection names: > ASMCLI ‑list ‑collections ‑showobjectid • When you specify an ‑objectID= parameter, the command parser ignores any subsequent ‑volume=, ‑collection=, and ‑component= parameters. offpeak • Used with: smart, verify subcommands • Specify the ‑offpeak parameter to schedule Checksum Verification during the offpeak Global Verification times (predicted periods of low computer use). When you specify ‑offpeak, you must also specify the ‑checksum parameter. • You can specify that this parameter can be used with the ‑smart command if you specify either ‑checksum or ‑verify, or both. • You can also specify the ‑offpeak parameter with the ‑verify command. • If you do not specify either the ‑offpeak parameter or the ‑remote parameter, Checksum Verification begins immediately after Smart Copy completion. promoteandverify • Used with: smart subcommand • Specify ‑promoteandverify to perform Checksum Verification directly on a promoted Exchange replica which will pause replication until the operation has completed. readwrite • Used with: mount subcommand • Specify the ‑readwrite parameter to enable both reads from and writes to the mounted volume. If not specified, the volume is mounted read‑only. recovery • Used with: smart subcommand • Specify ‑recovery to perform Checksum Verification or Soft Recovery (or both) on the Smart Copy. You can use this command only when making copies of Exchange objects. • You can specify the ‑recovery subcommand together with the ‑checksum subcommand option to perform both operations simultaneously. If you do not specify either the -smart or s subcommands, the ‑recovery parameter is ignored. retry= n • Used with: mount, unmount, restore subcommands • Specify the ‑retry= parameter with an integer value indicating the number of times to retry the operation if unsuccessful. remote • Used with: smart, verify subcommands • Specify the ‑remote parameter to schedule Checksum Verification on a remote computer instead of the local computer. If configured on the remote computer, Checksum Verification (and Soft Recovery, if specified), runs during the offpeak Global Verification times. Configure the remote computer to find and verify the newly‑created backup document. • You can specify that this parameter can be used with the ‑smart command if you specify either ‑checksum or ‑verify or both. • You can also specify the ‑remote parameter with the ‑verify command. • If you do not specify the ‑remote parameter, Checksum Verification begins immediately after Smart Copy completion. • Global Verification schedule times default to 8 p.m. to 6 a.m. local time. You can change these times by adjusting the Global Verification window in the ASM/ME GUI. • See Verification Settings. • See Run Checksum Verification and Soft Recovery on a Remote Host for information about configuring the remote computer. scheduleID= • Used with: smart subcommand 106 Using the Command Line Interface

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134

Alternatively, use the following command to display all component names:
ASMCLI
list
components
showobjectid
Collection Operations — Specify a collection name. A collection name has the following format:
Collection
{ascii_string}
For example:
Collection{exchange_collection}
You can obtain the collection name from the
ASM/ME GUI Collections
node by browsing an individual collection’s properties.
Alternatively, use the following command to display of all Collection names:
> ASMCLI
list
collections
showobjectid
When you specify an
objectID=
parameter, the command parser ignores any subsequent
volume=
,
collection=
, and
component=
parameters.
offpeak
Used with:
smart
,
verify
subcommands
Specify the
offpeak
parameter to schedule
Checksum Verification
during the offpeak Global Verification times (predicted
periods of low computer use). When you specify
offpeak
, you must also specify the
checksum
parameter.
You can specify that this parameter can be used with the
smart
command if you specify either
checksum
or
verify
, or both.
You can also specify the
offpeak
parameter with the
verify
command.
If you do not specify either the
offpeak
parameter or the
remote
parameter,
Checksum Verification
begins immediately
after Smart Copy completion.
promoteandverify
Used with:
smart
subcommand
Specify
promoteandverify
to perform
Checksum Verification
directly on a promoted Exchange replica which will pause
replication until the operation has completed.
readwrite
Used with:
mount
subcommand
Specify the
readwrite
parameter to enable both reads from and writes to the mounted volume. If not specified, the volume is
mounted read
only.
recovery
Used with:
smart
subcommand
Specify
recovery
to perform
Checksum Verification
or
Soft Recovery
(or both) on the Smart Copy. You can use this
command only when making copies of Exchange objects.
You can specify the
recovery
subcommand together with the
checksum
subcommand option to perform both operations
simultaneously. If you do not specify either the
–smart
or
s
subcommands, the
recovery
parameter is ignored.
retry=
n
Used with:
mount
,
unmount
,
restore
subcommands
Specify the
retry=
parameter with an integer value indicating the number of times to retry the operation if unsuccessful.
remote
Used with:
smart
,
verify
subcommands
Specify the
remote
parameter to schedule
Checksum Verification
on a remote computer instead of the local computer. If
configured on the remote computer, Checksum Verification (and Soft Recovery, if specified), runs during the offpeak Global
Verification times. Configure the remote computer to find and verify the newly
created backup document.
You can specify that this parameter can be used with the
smart
command if you specify either
checksum
or
verify
or both.
You can also specify the
remote
parameter with the
verify
command.
If you do not specify the
remote
parameter,
Checksum Verification
begins immediately after Smart Copy completion.
Global Verification schedule times default to 8 p.m. to 6 a.m. local time. You can change these times by adjusting the Global
Verification window in the ASM/ME GUI.
See
Verification Settings
.
See
Run Checksum Verification and Soft Recovery on a Remote Host
for information about configuring the remote computer.
scheduleID=
Used with:
smart
subcommand
106
Using the Command Line Interface