Dell External OEMR 2970 User Guide - Page 141
omreport Fan Status, omreport Temperature Probe Commands
View all Dell External OEMR 2970 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 141 highlights
Table 8-9. omreport Temperature Probe Commands Required Command Levels (1, 2, 3) Optional name=value pairs Use and name=value pair controller=id enclosure= info=temps index=n Displays the specified temperature probe. where id is the controller number and the enclosure number and "n" is the number of a temperature probe. For example: controller=0 enclosure=2 info=temps index=1 omreport Fan Status Table 8-10. omreport Fan Status Required Command Levels (1, 2, 3) Optional name=value pairs Use and name=value pair omreport storage enclosure Displays property information for all enclosures attached to the system. controller=id enclosure= Displays the fans for the specified info=fans enclosure. where id is the controller number and the enclosure number. For example: controller=0 enclosure=2 NOTE: For SCSI controllers, the ID specified in enclosure= is the connector number and for Serial Attached SCSI (SAS) controllers, ID is the connectorNumber:EnclosureIndex. controller=id enclosure= info=fans index=n Displays the specified fan. where id is the controller number and the enclosure number and "n" is the number of a fan. For example: controller=0 enclosure=2 info=fans index=1 Using the Storage Management Service 141