Dell External OEMR 2970 User Guide - Page 184

omconfig Reset All Temperature Probe Thresholds, omconfig Blink

Page 184 highlights

Example Syntax For example, you may want to specify the minimum and maximum warning thresholds for all temperature probes to 10 and 40° Celsius. Example for SAS Controllers In this example, the temperature probes reside in enclosure 3 attached to connector 2 on controller 1. To set the thresholds for all temperature probes to 10 and 40° Celsius, enter: omconfig storage enclosure action=setalltempprobes controller=1 enclosure=2:3 minwarn=10 maxwarn=40 omconfig Reset All Temperature Probe Thresholds Use the following omconfig command syntax to reset the minimum and maximum warning temperature thresholds back to their default value for all temperature probes in the enclosure. NOTE: This command is not supported on SCSI RAID controllers. Complete Syntax omconfig storage enclosure action=resetalltempprobes controller=id enclosure= where id is the controller ID. The variable specifies the enclosure. Example Syntax For example, you may want to reset the thresholds for all temperature probes in enclosure 2 on controller 1. Example for SAS Controllers In this example, the temperature probes reside in enclosure 3 attached to connector 2 on controller 1. To reset the thresholds for all temperature probes, enter: omconfig storage enclosure action=resetalltempprobes controller=1 enclosure=2:3 omconfig Blink Use the following omconfig command to blink the light-emitting diodes (LEDs) on the enclosure. Complete Syntax omconfig storage enclosure action=blink controller=id enclosure= where id is the controller ID. The variable specifies the enclosure. 184 Using the Storage Management Service

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226

184
Using the Storage Management Service
Example Syntax
For example, you may want to specify the minimum and maximum warning thresholds for all
temperature probes to 10 and 40
°
Celsius.
Example for SAS Controllers
In this example, the temperature probes reside in enclosure 3 attached to connector 2 on controller 1.
To set the thresholds for all temperature probes to 10 and 40
°
Celsius, enter:
omconfig storage enclosure action=setalltempprobes controller=1
enclosure=2:3 minwarn=10 maxwarn=40
omconfig Reset All Temperature Probe Thresholds
Use the following
omconfig
command syntax to reset the minimum and maximum warning temperature
thresholds back to their default value for all temperature probes in the enclosure.
NOTE:
This command is not supported on SCSI RAID controllers.
Complete Syntax
omconfig storage enclosure action=resetalltempprobes controller=id
enclosure=<ENCLOSUREID>
where
id
is the controller ID. The
<ENCLOSUREID>
variable specifies the enclosure.
Example Syntax
For example, you may want to reset the thresholds for all temperature probes in enclosure 2 on
controller 1.
Example for SAS Controllers
In this example, the temperature probes reside in enclosure 3 attached to connector 2 on controller 1.
To reset the thresholds for all temperature probes, enter:
omconfig storage enclosure action=resetalltempprobes controller=1
enclosure=2:3
omconfig Blink
Use the following omconfig command to blink the light-emitting diodes (LEDs) on the enclosure.
Complete Syntax
omconfig storage enclosure action=blink controller=id enclosure=
<ENCLOSUREID>