Dell External OEMR 2970 User Guide - Page 180
omconfig Enable Enclosure Alarm, For example
View all Dell External OEMR 2970 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 180 highlights
omconfig Enable Enclosure Alarm Use the following omconfig command syntax to enable the enclosure alarm: Complete Syntax omconfig storage enclosure action=enablealarm controller=id enclosure= where id is the controller ID. The variable specifies the enclosure. Example for SCSI, SATA, and ATA Controllers: For example, to enable the alarm on the enclosure attached to connector 2 on controller 1, enter: omconfig storage enclosure action=enablealarm controller=1 enclosure=2 Example for SAS Controllers: For example, to enable the alarm on enclosure 2 attached to connector 1 on controller 1, enter: omconfig storage enclosure action=enablealarm controller=1 enclosure=1:2 omconfig Disable Enclosure Alarm Use the following omconfig command syntax to disable the enclosure alarm. Complete Syntax omconfig storage enclosure action=disablealarm controller=id enclosure= where id is the controller ID. The variable specifies the enclosure. Example for SCSI, SATA, and ATA Controllers: For example, to disable the alarm on the enclosure attached to connector 2 on controller 1, enter: omconfig storage enclosure action=disablealarm controller=1 enclosure=2 Example for SAS Controllers: For example, to disable the alarm on enclosure 2 attached to connector 1 on controller 1, enter: omconfig storage enclosure action=disablealarm controller=1 enclosure=1:2 180 Using the Storage Management Service