Dell External OEMR 2970 User Guide - Page 182

omconfig Set Temperature Probe Thresholds, enclosure=1:2 assetname=encl43

Page 182 highlights

Complete Syntax omconfig storage enclosure action=setassetname controller=id enclosure= assetname= where id is the controller ID. The variable specifies the enclosure. In this syntax, is a user-specified alphanumeric string. Example for SCSI, SATA, and ATA Controllers: For example, to specify the asset name to encl43 for the enclosure attached to connector 2 on controller 1, enter: omconfig storage enclosure action=setassetname controller=1 enclosure=2 assetname=encl43 Example for SAS Controllers: For example, to specify the asset name to encl43 for enclosure 2 attached to connector 1 on controller 1, enter: omconfig storage enclosure action=setassetname controller=1 enclosure=1:2 assetname=encl43 omconfig Set Temperature Probe Thresholds Use the following omconfig command syntax to set the minimum and maximum warning temperature thresholds for a specified temperature probe. NOTE: This command is not supported on SAS controllers. Complete Syntax omconfig storage enclosure action=settempprobes controller=id enclosure= index=id minwarn=n maxwarn=n where id is the controller ID and the temperature probe ID. The variable specifies the enclosure. In this syntax, "n" is a user-specified value for the temperature in Celsius. Example Syntax For example, you may want to specify the minimum and maximum warning thresholds for temperature probe 3 to 10 and 40° Celsius. 182 Using the Storage Management Service

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226

182
Using the Storage Management Service
Complete Syntax
omconfig storage enclosure action=setassetname controller=id
enclosure=<ENCLOSUREID> assetname=<string>
where
id
is the controller ID. The
<ENCLOSUREID>
variable specifies the enclosure.
In this syntax, <string> is a user-specified alphanumeric string.
Example for SCSI, SATA, and ATA Controllers
:
For example, to specify the asset name to encl43 for the enclosure attached to connector 2 on
controller 1, enter:
omconfig storage enclosure action=setassetname controller=1
enclosure=2 assetname=encl43
Example for SAS Controllers
:
For example, to specify the asset name to encl43 for enclosure 2 attached to connector 1 on
controller 1, enter:
omconfig storage enclosure action=setassetname controller=1
enclosure=1:2 assetname=encl43
omconfig Set Temperature Probe Thresholds
Use the following
omconfig
command syntax to set the minimum and maximum warning temperature
thresholds for a specified temperature probe.
NOTE:
This command is not supported on SAS controllers.
Complete Syntax
omconfig storage enclosure action=settempprobes controller=id
enclosure=<ENCLOSUREID> index=id minwarn=n maxwarn=n
where
id
is the controller ID and the temperature probe ID. The
<ENCLOSUREID>
variable specifies
the enclosure.
In this syntax, “n” is a user-specified value for the temperature in Celsius.
Example Syntax
For example, you may want to specify the minimum and maximum warning thresholds for temperature
probe 3 to 10 and 40
°
Celsius.