Dell External OEMR 2970 User Guide - Page 177

omconfig Battery Commands, omconfig Recondition Battery, omconfig Start Battery Learn Cycle

Page 177 highlights

omconfig Battery Commands The following sections provide the omconfig command syntax required to execute battery tasks. Table 8-24. omconfig Battery Commands Required Command Levels (1, 2, 3) Optional name=value pairs omconfig storage battery action=recondition controller=id battery=id action=startlearn controller=id battery=id action=delaylearn controller=id battery=id days=d hours=h omconfig Recondition Battery Use the following omconfig command to recondition a controller battery. For more information on batteries and the recondition process, see the online help. Complete Syntax omconfig storage battery action=recondition controller=id battery=id where id is the controller ID and battery ID as reported by the omreport command. To obtain this value, enter omreport storage controller to display the controller IDs and then enter omreport storage battery controller=ID to display the ID for the controller battery. Example Syntax For example, to recondition the battery on controller 1, enter: omconfig storage battery action=recondition controller=1 battery=0 omconfig Start Battery Learn Cycle Use the following omconfig command to start the battery learn cycle. Complete Syntax omconfig storage battery action=startlearn controller=id battery=id where id is the controller ID and battery ID as reported by the omreport command. To obtain this value, enter omreport storage controller to display the controller IDs and then enter omreport storage battery controller=ID to display the ID for the controller battery. Example Syntax For example, to start the learn cycle on controller 1, enter: omconfig storage battery action=startlearn controller=1 battery=0 Using the Storage Management Service 177

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226

Using the Storage Management Service
177
omconfig Battery Commands
The following sections provide the
omconfig
command syntax required to execute battery tasks.
omconfig Recondition Battery
Use the following
omconfig
command to recondition a controller battery. For more information on
batteries and the recondition process, see the online help.
Complete Syntax
omconfig storage battery action=recondition controller=id battery=id
where
id
is the controller ID and battery ID as reported by the
omreport
command. To obtain this value,
enter
omreport storage controller
to display the controller IDs and then enter
omreport storage battery
controller=ID
to display the ID for the controller battery.
Example Syntax
For example, to recondition the battery on controller 1, enter:
omconfig storage battery action=recondition controller=1 battery=0
omconfig Start Battery Learn Cycle
Use the following
omconfig
command to start the battery learn cycle.
Complete Syntax
omconfig storage battery action=startlearn controller=id battery=id
where
id
is the controller ID and battery ID as reported by the
omreport
command. To obtain this value,
enter
omreport storage controller
to display the controller IDs and then enter
omreport storage battery
controller=ID
to display the ID for the controller battery.
Example Syntax
For example, to start the learn cycle on controller 1, enter:
omconfig storage battery action=startlearn controller=1 battery=0
Table 8-24.
omconfig Battery Commands
Required Command Levels (1, 2, 3)
Optional name=value pairs
omconfig storage battery
action=recondition controller=id battery=id
action=startlearn controller=id battery=id
action=delaylearn controller=id battery=id
days=d hours=h