omconfig chassis remoteaccess, Disables IPMI over LAN.
View all Dell External OEMR 2970 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 76 highlights
The output from the omconfig chassis remoteaccess command lists each of the available configurations. Table 4-3 shows the valid parameters: Table 4-12. omconfig chassis remoteaccess name=value pair 1 config= config=advsol name=value pair 2 characcuminterval=number charsendthreshold=number config=nic enable=true | false encryptkey=text confirmencryptkey=text gateway=Gateway enablenic=true | false IP address=IP Description number: Sets the character accumulate interval in 5 millisecond intervals. number: Sets the number of characters. BMC automatically sends a serial over LAN data packet that contains this number of characters as soon as this number of characters (or greater) has been accepted from the baseboard serial controller into the BMC. true: Enables IPMI over LAN. false: Disables IPMI over LAN. text: Text used for encryption and confirmation of encryption. NOTE: The option text is supported only on PowerEdge x9xx systems. Gateway: Sets a gateway address if you have selected static as the IP address source for the BMC LAN interface. true: Enables DRAC NIC. false: Disables DRAC NIC NOTE: The option enablenic is supported on PowerEdge x9xx systems that have DRAC 5 installed. ip: Sets the IP address if you have selected static as the IP address source for the BMC LAN interface. 76 omconfig: Managing Components Using the Instrumentation Service