Dell External OEMR 2970 User Guide - Page 76

omconfig chassis remoteaccess, Disables IPMI over LAN.

Page 76 highlights

The output from the omconfig chassis remoteaccess command lists each of the available configurations. Table 4-3 shows the valid parameters: Table 4-12. omconfig chassis remoteaccess name=value pair 1 config= config=advsol name=value pair 2 characcuminterval=number charsendthreshold=number config=nic enable=true | false encryptkey=text confirmencryptkey=text gateway=Gateway enablenic=true | false IP address=IP Description number: Sets the character accumulate interval in 5 millisecond intervals. number: Sets the number of characters. BMC automatically sends a serial over LAN data packet that contains this number of characters as soon as this number of characters (or greater) has been accepted from the baseboard serial controller into the BMC. true: Enables IPMI over LAN. false: Disables IPMI over LAN. text: Text used for encryption and confirmation of encryption. NOTE: The option text is supported only on PowerEdge x9xx systems. Gateway: Sets a gateway address if you have selected static as the IP address source for the BMC LAN interface. true: Enables DRAC NIC. false: Disables DRAC NIC NOTE: The option enablenic is supported on PowerEdge x9xx systems that have DRAC 5 installed. ip: Sets the IP address if you have selected static as the IP address source for the BMC LAN interface. 76 omconfig: Managing Components Using the Instrumentation Service

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226

76
omconfig: Managing Components Using the Instrumentation Service
The output from the
omconfig chassis remoteaccess
command lists each of the available configurations.
Table 4-3 shows the valid parameters:
Table 4-12.
omconfig chassis remoteaccess
name=value pair 1
config=
name=value pair 2
Description
config=advsol
characcuminterval=number
number
: Sets the character accumulate
interval in 5 millisecond intervals.
charsendthreshold=number
number
: Sets the number of characters. BMC
automatically sends a serial over LAN data
packet that contains this number of
characters as soon as this number of
characters (or greater) has been accepted
from the baseboard serial controller into
the BMC.
config=nic
enable=true | false
true
: Enables IPMI over LAN.
false
: Disables IPMI over LAN.
encryptkey=text
confirmencryptkey=text
text:
Text used for encryption and
confirmation of encryption.
NOTE:
The option
text
is supported only on
PowerEdge
x
9
xx
systems.
gateway=Gateway
Gateway
: Sets a gateway address if you have
selected static as the IP address source for the
BMC LAN interface.
enablenic=true | false
true
: Enables DRAC NIC.
false
: Disables DRAC NIC
NOTE:
The option
enablenic
is supported on
PowerEdge
x
9
xx
systems that have DRAC 5
installed.
IP address=IP
ip
: Sets the IP address if you have selected
static as the IP address source for the BMC
LAN interface.