Dell External OEMR 2970 User Guide - Page 93

omconfig system platformevents

Page 93 highlights

omconfig system platformevents Use the omconfig system platformevents command to configure shutdown action, if any, to be taken for a specific platform event. You can also enable or disable platform event filter alert generation. NOTICE: If you set a platform event shutdown action to anything other than "none", your system will forcefully shutdown when the specified event occurs. This shutdown is initiated by firmware and is carried out without first shutting down the operating system or any of the applications running on your system. Table 4-23 shows the valid parameters for the command. NOTE: Alert settings are mutually exclusive and can be set one at a time only. The action settings are also mutually exclusive and can be set one at a time only. However, alert and action settings are not mutually exclusive of each other. Table 4-23. Shutdown Action Shutdown Action alert=disable alert=enable action=none action=powercycle action=poweroff action=reboot Description Disables the SNMP alert. Enables the SNMP alert to be sent. Takes no action when the system is hung or has crashed. Turns the electrical power to the system off, pauses, turns the power on, and reboots the system. Turns off the electrical power to the system. Forces the operating system to shut down and initiates system startup, performs BIOS checks, and reloads the operating system. Table 4-24 lists the components and the events for which you can set platform events. Components are listed in alphabetical order, except that warning events always precede failure events for a component. Table 4-24. omconfig system platformevents Event Name alertsenable=true | false event=batterywarn event=batteryfail event=discretevolt Description true: Enables generation of platform event filter alerts. false: Disables generation of platform event filter alerts. NOTE: This setting is independent of the individual platform event filter alert settings. For a platform event filter to generate an alert, both the individual alert and the global event alert must be enabled. Sets action or enables/disables alert generation when a battery device detects that the battery is pending a failure condition. Sets action or enables/disables alert generation when a battery device detects that the battery has failed. Sets action or enables/disables alert generation when a discrete voltage probe detects that the voltage is too low for proper operation. omconfig: Managing Components Using the Instrumentation Service 93

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226

omconfig: Managing Components Using the Instrumentation Service
93
omconfig system platformevents
Use the
omconfig system platformevents
command to configure shutdown action, if any, to be taken for a
specific platform event. You can also enable or disable platform event filter alert generation.
NOTICE:
If you set a platform event shutdown action to anything other than "none", your system will forcefully
shutdown when the specified event occurs. This shutdown is initiated by firmware and is carried out without first
shutting down the operating system or any of the applications running on your system.
Table 4-23 shows the valid parameters for the command.
NOTE:
Alert settings are mutually exclusive and can be set one at a time only. The action settings are also mutually
exclusive and can be set one at a time only. However, alert and action settings are not mutually exclusive of
each other.
Table 4-24 lists the components and the events for which you can set platform events. Components are
listed in alphabetical order, except that warning events always precede failure events for a component.
Table 4-23.
Shutdown Action
Shutdown Action
Description
alert=disable
Disables the SNMP alert.
alert=enable
Enables the SNMP alert to be sent.
action=none
Takes no action when the system is hung or has crashed.
action=powercycle
Turns the electrical power to the system off, pauses, turns the power on, and
reboots the system.
action=poweroff
Turns off the electrical power to the system.
action=reboot
Forces the operating system to shut down and initiates system startup,
performs BIOS checks, and reloads the operating system.
Table 4-24.
omconfig system platformevents
Event Name
Description
alertsenable=true | false
true
: Enables generation of platform event filter alerts.
false
: Disables generation of platform event filter alerts.
NOTE:
This setting is independent of the individual platform event filter alert settings.
For a platform event filter to generate an alert, both the individual alert and the global
event alert must be enabled.
event=batterywarn
Sets action or enables/disables alert generation when a battery device detects that
the battery is pending a failure condition.
event=batteryfail
Sets action or enables/disables alert generation when a battery device detects that
the battery has failed.
event=discretevolt
Sets action or enables/disables alert generation when a discrete voltage probe
detects that the voltage is too low for proper operation.