Dell External OEMR 2970 User Guide - Page 62

The output from the, command lists each of the available configurations.

Page 62 highlights

The output from the omconfig chassis bmc command lists each of the available configurations. Table 4-3 shows the valid parameters: Table 4-3. omconfig chassis bmc name=value pair 1 config= config=advsol name=value pair 2 characcuminterval=number charsendthreshold=number config=nic enable=true | false encryptkey=text gateway=gateway enablenic=true | false IP address=IP ipsource=static | dhcp | systemsoftware Description number: Sets the character accumulate interval in 5 millisecond intervals. number: Sets the number of characters. BMC automatically sends a serial over LAN data packet that contains this number of characters as soon as this number of characters (or greater) has been accepted from the baseboard serial controller into the BMC. true: Enables IPMI over LAN. false: Disables IPMI over LAN. text: Text to encrypt IPMI sessions. NOTE: The option text is supported only on PowerEdge x9xx systems. Gateway: Sets a gateway address if you have selected static as the IP address source for the BMC LAN interface. true: Enables the DRAC NIC. false: Disables the DRAC NIC NOTE: The option enablenic is supported only on PowerEdge x9xx systems that have DRAC 5 installed. IP: Sets the IP address if you have selected static as the IP address source for the BMC LAN interface. static: Static if the IP address of the BMC LAN interface is a fixed, assigned IP address. dhcp: DHCP if the source of the IP address of the BMC LAN interface is the dynamic host configuration protocol. systemsoftware: System software if the source of the IP address of the BMC LAN interface is from the system software. NOTE: Not all commands may be supported on the system. 62 omconfig: Managing Components Using the Instrumentation Service

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226

62
omconfig: Managing Components Using the Instrumentation Service
The output from the
omconfig chassis bmc
command lists each of the available configurations.
Table 4-3 shows the valid parameters:
Table 4-3.
omconfig chassis bmc
name=value pair 1
config=
name=value pair 2
Description
config=advsol
characcuminterval=number
number
: Sets the character accumulate interval
in 5 millisecond intervals.
charsendthreshold=number
number
: Sets the number of characters. BMC
automatically sends a serial over LAN data
packet that contains this number of characters
as soon as this number of characters (or greater)
has been accepted from the baseboard serial
controller into the BMC.
config=nic
enable=true | false
true
: Enables IPMI over LAN.
false
: Disables IPMI over LAN.
encryptkey=text
text:
Text to encrypt IPMI sessions.
NOTE:
The option
text
is supported only on
PowerEdge
x
9
xx
systems.
gateway=gateway
Gateway:
Sets a gateway address if you have
selected static as the IP address source for the
BMC LAN interface.
enablenic=true | false
true
: Enables the DRAC NIC.
false
: Disables the DRAC NIC
NOTE:
The option
enablenic
is supported only on
PowerEdge
x
9
xx
systems that have DRAC 5
installed.
IP address=IP
IP
: Sets the IP address if you have selected
static as the IP address source for the BMC
LAN interface.
ipsource=static | dhcp |
systemsoftware
static
: Static if the IP address of the BMC LAN
interface is a fixed, assigned IP address.
dhcp
: DHCP if the source of the IP address of
the BMC LAN interface is the dynamic host
configuration protocol.
systemsoftware
: System software if the source
of the IP address of the BMC LAN interface is
from the system software.
NOTE:
Not all commands may be supported on