Dell PowerEdge C6400 EMC Installation and Service Manual - Page 33

Expanded operating temperature specifications, Operating temperature derating specifications

Page 33 highlights

Expanded operating temperature specifications Table 16. Expanded operating temperature Expanded operating temperature Specifications Continuous operation 5°C-40°C at 5% to 85% RH with maximum 29°C dew point. NOTE: Outside the standard operating temperature (10°C-35°C), the system can operate continuously in temperatures as low as 5°C and as high as 40°C. ≤ 1% of annual operating hours For temperatures between 35°C and 40°C, derate maximum allowable temperature by 1°C per 175 m above 950 m (1°F per 319 ft). -5°C-45°C at 5% to 90% RH with maximum 29°C dew point. NOTE: Outside the standard operating temperature (10°C-35°C), the system can operate down to -5°C or up to 45°C for a maximum of 1% of its annual operating hours. For temperatures between 40°C-45°C, derate maximum allowable temperature by 1°C per 125 m above 950 m (1°F per 228 ft). NOTE: When operating in the expanded temperature range, system performance may be impacted. NOTE: When operating in the expanded temperature range, ambient temperature warnings may be reported in the System Event Log. Operating temperature derating specifications Table 17. Operating temperature Operating temperature derating < 35°C (95°F) Specifications Maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 meters (3,117 ft). 35°C-40°C (95°F-104°F) Maximum temperature is reduced by 1°C/175 m (1°F/319 ft) above 950 meters (3,117 ft). > 45°C (113°F) Maximum temperature is reduced by 1°C/125 m (1°F/228 ft) above 950 meters (3,117 ft). Relative humidity specifications Table 18. Relative humidity specifications Relative humidity Storage Operating Specifications 5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere must be noncondensing always. 10% to 80% relative humidity with 29°C (84.2°F) maximum dew point. Temperature specifications Table 19. Temperature specifications Temperature Storage Specifications -40°C-65°C (-40°F to 149°F) Technical specifications 33

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

Expanded operating temperature specifications
Table 16. Expanded operating temperature
Expanded operating temperature
Specifications
Continuous operation
5°C–40°C at 5% to 85% RH with maximum 29°C dew point.
NOTE:
Outside the standard operating temperature (10°C–35°C), the system
can operate continuously in temperatures as low as 5°C and as high as 40°C.
For temperatures between 35°C and 40°C, derate maximum allowable temperature by 1°C
per 175 m above 950 m (1°F per 319 ft).
≤ 1% of annual operating hours
–5°C–45°C at 5% to 90% RH with maximum 29°C dew point.
NOTE:
Outside the standard operating temperature (10°C–35°C), the system
can operate down to –5°C or up to 45°C for a maximum of 1% of its annual
operating hours.
For temperatures between 40°C-45°C, derate maximum allowable temperature by 1°C per
125 m above 950 m (1°F per 228 ft).
NOTE:
When operating in the expanded temperature range, system performance may be impacted.
NOTE:
When operating in the expanded temperature range, ambient temperature warnings may be reported in the
System Event Log.
Operating temperature derating specifications
Table 17. Operating temperature
Operating temperature derating
Specifications
< 35°C (95°F)
Maximum temperature is reduced by 1°C/300 m (1°F/547 ft)
above 950 meters (3,117 ft).
35°C–40°C (95°F–104°F)
Maximum temperature is reduced by 1°C/175 m (1°F/319 ft)
above 950 meters (3,117 ft).
> 45°C (113°F)
Maximum temperature is reduced by 1°C/125 m (1°F/228 ft)
above 950 meters (3,117 ft).
Relative humidity specifications
Table 18. Relative humidity specifications
Relative humidity
Specifications
Storage
5% to 95% RH with 33°C (91°F) maximum dew point.
Atmosphere must be noncondensing always.
Operating
10% to 80% relative humidity with 29°C (84.2°F) maximum dew
point.
Temperature specifications
Table 19. Temperature specifications
Temperature
Specifications
Storage
–40°C–65°C (–40°F to 149°F)
Technical specifications
33