Dell PowerEdge C6400 EMC Installation and Service Manual - Page 65
Installing the right midplane, Removing the left midplane
View all Dell PowerEdge C6400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 65 highlights
Installing the right midplane Prerequisites NOTE: You must route the cables properly on the chassis to prevent them from being pinched or crimped. 1. Follow the safety guidelines listed in Safety instructions. Steps 1. Using the Phillips #1 screwdriver, connect and secure the power cables to the midplane. 2. Place the midplane into the chassis. 3. Using the Phillips #1 screwdriver, tighten the screws that secure the midplane to the chassis. Figure 52. Installing the right midplane Next steps 1. Reconnect all the disconnected cables. 2. Install the cooling fan cage. 3. Install the sleds into the enclosure. 4. Follow the procedure listed in After working inside your enclosure. Removing the left midplane Prerequisites NOTE: Observe the routing of the cables on the chassis as you remove them from the system. Route these cables properly when you replace them to prevent the cables from being pinched or crimped. 1. Follow the safety guidelines listed in Safety instructions.. 2. Follow the procedure listed in Before working inside your enclosure. 3. Remove all the sleds from the enclosure. 4. Remove the cooling fan cage. Installing and removing enclosure components 65