Dell PowerEdge C6400 EMC Installation and Service Manual - Page 56
Power interposer board, Removing the power interposer board
View all Dell PowerEdge C6400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 56 highlights
Figure 40. Installing the cooling fan cage Next steps 1. Install the cooling fans. 2. Follow the procedure listed in After working inside your enclosure. 3. Check the management software to see if all the fans are rotating at the optimal speed. Power interposer board Removing the power interposer board Prerequisites WARNING: Allow the power interposer board (PIB) to discharge after you power off the system. Handle the PIB by the edges and avoid touching the contact surfaces of the connectors. 1. Follow the safety guidelines listed in Safety instructions. 2. Follow the procedure listed in Before working inside your enclosure. 3. Remove the power supply units. 4. Disconnect all the cables from the PIB except for the mid-plane power cables. Steps 1. To release the PIB from the lock on the chassis, pull the blue release latch. 2. Holding the release latch, lift the PIB up and away from the guide hooks on the chassis. 3. Using the Phillips #2 screwdriver, remove the screws that secure the mid-plane power cables to the PIB. 56 Installing and removing enclosure components