Dell PowerEdge C6400 EMC Installation and Service Manual - Page 35
Maximum shock specifications, Fresh Air Operation, Fresh Air operation restrictions
View all Dell PowerEdge C6400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 35 highlights
Table 22. Maximum vibration specifications (continued) Maximum vibration Specifications Storage 1.88 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested). Maximum shock specifications Table 23. Maximum shock specifications Maximum shock Operating Specifications 24 executed shock pulses 6 G in the positive and negative x, y, z axis for up to 11 ms (four pulses on each side of the system). Storage Six consecutively executed shock pulses of 71 G in the positive and negative x, y, z axes for up to 2 ms (one pulse on each side of the system). Maximum altitude specifications Table 24. Maximum altitude specifications Maximum altitude Operating Specifications 3048 m (10,000 ft) Storage 12,000 m (39,370 ft) Fresh Air Operation Fresh Air operation restrictions • Processors with a TDP greater than 105 W are not supported • Support for processors of 85 W and below without PERC restrictions • 3.5-inch drive configuration is not supported • 114-mm heat sink is required for the processor in CPU1 socket • Kerby-flat OCP is not supported • M.2 card on DCS Mezzanine slot is not supported. • NVMe SSD is not supported • AEP DIMM and LRDIMM are not supported • PCIe cards greater than 25 W are not supported • H730 PERC and H330 support for 105-W processors • No PERC restrictions for 85 W and lesser TDP processors Technical specifications 35