Dell PowerEdge R200 Hardware Owner's Manual (PDF) - Page 21
DIMM1_B, Table 1-4., System Messages, Message, Causes, Corrective Actions
View all Dell PowerEdge R200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
Table 1-4. System Messages (continued) Message Causes Corrective Actions Decreasing available memory One or more memory Reinstall the memory modules might be modules and, if necessary, improperly seated or faulty. replace them. See "System Memory" on page 81. See "Troubleshooting System Memory" on page 108. Diskette read failure Faulty or improperly inserted diskette. Replace the diskette. Diskette subsystem Faulty diskette drive or reset failed optical drive controller. Ensure that the diskette drive and optical drive cables are properly connected. See "Troubleshooting a USB Device" on page 102 and "Troubleshooting an Optical Drive" on page 110. If the problem persists, see "Getting Help" on page 127. Drive not ready Diskette missing or improperly inserted in diskette drive. Reinsert or replace the diskette. Error: Incorrect memory configuration. Ensure memory in slots DIMM1_A and DIMM1_B, DIMM2_A and DIMM2_B match identically in size, speed and rank. The installed memory modules are not matched pairs. See "Memory Module Installation Guidelines" on page 81. About Your System 21