Dell PowerEdge R200 Hardware Owner's Manual (PDF) - Page 42

Console Redirection Screen - bmc

Page 42 highlights

Table 2-6. Integrated Devices Screen Options (continued) Option Serial Port 1 (COM1 default) Speaker (On default) Description Serial Port options are COM1, COM3, BMC Serial, BMC NIC, COM1/BMC, and Off. If an optional remote access controller (RAC) is installed in the system, RAC is an additional option. Serial Port shares three usage models. For standard usage, Serial Port attempts to use COM1 first, and then COM3. For BMC usage, serial port 1 uses the COM1 address and communication can be either via the serial port or the integrated shared NIC. RAC control uses only the COM1 address. The COM1/BMC setting allows you to toggle the system between a COM1 setting and BMC Serial setting. In this mode, press to enter the BMC Serial setting and press to return to the COM1 setting. Off and COM3 are not available options when Console Redirection is set to use Serial Port 1. Enables or disables the system internal speaker. Console Redirection Screen Table 2-7 lists the options and descriptions for the information fields that appear on the Console Redirection screen. Table 2-7. Console Redirection Screen Options Option Description Console Redirection (Off default) Sets the console redirection feature to Off or Serial Port 1. Failsafe Baud Rate (115200 default) Displays if the failsafe baud rate is used for console redirection. Remote Terminal Type Select either VT 100/VT 220 or ANSI. (VT 100/VT 220 default) Redirection After Boot Enables or disables console redirection after your system (Enabled default) restarts. 42 Using the System Setup Program

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182

42
Using the System Setup Program
Console Redirection Screen
Table 2-7 lists the options and descriptions for the information fields that
appear on the
Console Redirection
screen.
Serial Port 1
(
COM1
default)
Serial Port
options are
COM1
,
COM3
,
BMC Serial
,
BMC NIC
,
COM1/BMC
,
and
Off
. If an optional remote
access controller (RAC) is installed in the system,
RAC
is
an additional option.
Serial Port
shares three usage models. For standard usage,
Serial Port
attempts to use COM1 first, and then COM3.
For BMC usage, serial port 1 uses the COM1 address and
communication can be either via the serial port or the
integrated shared NIC. RAC control uses only the COM1
address.
The
COM1/BMC
setting allows you to toggle the system
between a
COM1
setting and
BMC Serial
setting. In this
mode, press <ESC> to enter the BMC Serial setting and
press <ESC><q> to return to the
COM1
setting.
Off
and
COM3
are not available options when Console
Redirection is set to use Serial Port 1.
Speaker
(
On
default)
Enables or disables the system internal speaker.
Table 2-7.
Console Redirection Screen Options
Option
Description
Console Redirection
(
Off
default)
Sets the console redirection feature to
Off
or
Serial Port 1
.
Failsafe Baud Rate
(
115200
default)
Displays if the failsafe baud rate is used for console
redirection.
Remote Terminal Type
(
VT 100/VT 220
default)
Select either
VT 100/VT 220
or
ANSI
.
Redirection After Boot
(
Enabled
default)
Enables or disables console redirection after your system
restarts.
Table 2-6.
Integrated Devices Screen Options
(continued)
Option
Description