Table 1-4. System Messages (continued) Message Causes Corrective Actions Plug & Play Error encountered in Configuration Error initializing PCI device; faulty system board. Install the NVRAM_CLR jumper and reboot the system. See Figure 6-1 for jumper location. Check for a BIOS update. If the problem persists, see "Troubleshooting Expansion Cards" on page 113. If the problem persists, see "Getting Help" on page 127. Read fault Requested sector not found The operating system Replace the diskette. cannot read from the Ensure that the diskette diskette or hard drive, the and hard-drive cables are system could not find a properly connected. See particular sector on the "Troubleshooting a USB disk, or the requested sector Device" on page 102 or is defective. "Troubleshooting a Hard Drive" on page 111 for the appropriate drive(s) installed in your system. Remote Configuration update attempt failed System could not implement Remote Configuration request. Retry Remote Configuration. SATA port 0/1/2 Faulty drive. Parameters hard disk drive failure. configuration error Ensure that the hard drive cables are properly connected. See "Troubleshooting a Hard Drive" on page 111. SATA port 0/1/2 hard disk drive failure SATA port 0/1/2 hard disk drive auto-sensing error Faulty drive. INT13 call failure from the drive. Ensure that the hard drive cables are properly connected. See "Troubleshooting a Hard Drive" on page 111. 26 About Your System