HP MSA2324sa HP StorageWorks 2300 Family Modular Smart Array CLI reference gui - Page 116
show advanced-settings, Host Control of Caching
![]() |
View all HP MSA2324sa manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 116 highlights
show advanced-settings Description For API use, shows the settings for advanced system-configuration options. Syntax show advanced-settings Output Background Scrub Shows whether disks are automatically checked for disk defects to ensure system health. Partner Firmware Upgrade Shows whether component firmware versions are monitored and will be automatically upgraded on the partner controller. Utility Priority Priority at which jobs (such as vdisk verification and reconstruction but not background scrub) run with respect to I/O operations competing for the system's processors: High, Medium, or Low. SMART Shows whether Self-Monitoring Analysis and Reporting Technology is enabled or disabled for all disks, or is set to detect-only, which specifies that each new drive inserted in the system retains its current SMART setting. Dynamic Spare Configuration Shows whether the storage system will automatically designate a properly sized drive as a spare. Enclosure Polling Rate Shows the interval at which the storage system polls the EC (EMP) for status changes. Host Control of Caching Shows whether host control of write-back cache is enabled or disabled. When disabled, hosts cannot use the SCSI MODE SELECT command to change the storage system's cache setting. Sync Cache Mode Shows how the SCSI SYNCHRONIZE CACHE command is handled: • Immediate - Good status is returned immediately and cache content is unchanged. • Flush To Disk - Good status is returned only after all write-back data for the specified volume is flushed to disk. Missing LUN Response Missing LUN Response enables the host drivers to continue probing for LUNs until they reach the LUN to which they have access. • Not Ready - Sends a reply that there is a LUN where a gap has been created but that its "not ready." Sense data returned is sensekey = 2, code = 4, qualifier = 3. • Illegal Request - Sends a reply that there is a LUN but that the request is "illegal." Sense data returned is sensekey = 5, code = 25h, qualifier = 0. Controller Failure Shows whether the cache policy automatically changes to write-through when a controller fails. SuperCap Failure Shows whether the cache policy automatically changes to write-through when cache backup power is not fully charged or fails. CompactFlash Failure Shows whether the cache policy automatically changes to write-through when CompactFlash memory fails. Power Supply Failure Shows whether the cache policy automatically changes to write-through when a power supply fails. Fan Failure Shows whether the cache policy automatically changes to write-through when a fan fails. 116
![](/manual_guide/products/hewlettpackard-msa2312i-hp-storageworks-2300-family-modular-smart-array-cli-reference-guide-500912002-2010-2bf014b/116.png)