HP MSA2324sa HP StorageWorks 2300 Family Modular Smart Array CLI reference gui - Page 139

PHY disabled because drive slot is empty.

Page 139 highlights

Reason • 0x8001: PHY disabled because of error-count interrupts. • 0x8003: PHY disabled by PHY control page. • 0x8004: PHY is enabled but not ready. Appears for SC-1 PHYs when the partner I/O module is not installed. Appears for Drive, SC-1, or Ingress PHYs when a connection problem exists such as a broken connector. • 0x8006: PHY disabled because drive slot is empty. Example Show expander status for a single-enclosure system with an empty disk slot: # show expander-status Encl Ctlr Phy Type Status Elem Status Disabled Reason 1 A 0 Drive Enabled-Healthy OK Enabled 1 A 1 Drive Disabled Disabled Disabled ... 1 A 23 Drive Disabled OK Disabled 0x8006 1 A 0 SC-1 Enabled-Healthy OK Enabled 1 A 1 SC-1 Enabled-Healthy OK Enabled 1 A 0 SC-0 Enabled-Healthy OK Enabled ... 1 A 3 SC-0 Enabled-Healthy OK Enabled 1 A 0 Egress Enabled-Healthy Non-critical Enabled ... 1 A 3 Egress Enabled-Healthy Non-critical Enabled Encl Ctlr Phy Type Status Elem Status Disabled Reason 1 B 0 Drive Enabled-Healthy OK Enabled 1 B 1 Drive Enabled-Healthy OK Enabled ... 1 B 23 Drive Disabled OK Disabled 0x8006 1 B 0 SC-1 Enabled-Healthy OK Enabled 1 B 1 SC-1 Enabled-Healthy OK Enabled 1 B 0 SC-0 Enabled-Healthy OK Enabled ... 1 B 0 Egress Enabled-Healthy Non-critical Enabled ... 1 B 3 Egress Enabled-Healthy Non-critical Enabled See also • clear expander-status • set expander-fault-isolation • set expander-phy HP StorageWorks 2000 G2 Modular Smart Array CLI Reference Guide 139

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196

HP StorageWorks 2000 G2 Modular Smart Array CLI Reference Guide
139
Reason
0x8001
: PHY disabled because of error-count interrupts.
0x8003
: PHY disabled by PHY control page.
0x8004
: PHY is enabled but not ready. Appears for SC-1 PHYs when the partner I/O module is
not installed. Appears for Drive, SC-1, or Ingress PHYs when a connection problem exists such as
a broken connector.
0x8006
: PHY disabled because drive slot is empty.
Example
Show expander status for a single-enclosure system with an empty disk slot:
# show expander-status
Encl
Ctlr Phy
Type
Status
Elem Status
Disabled
Reason
-------------------------------------------------------------------------------
1
A
0
Drive
Enabled-Healthy
OK
Enabled
1
A
1
Drive
Disabled
Disabled
Disabled
...
1
A
23
Drive
Disabled
OK
Disabled
0x8006
1
A
0
SC-1
Enabled-Healthy
OK
Enabled
1
A
1
SC-1
Enabled-Healthy
OK
Enabled
1
A
0
SC-0
Enabled-Healthy
OK
Enabled
...
1
A
3
SC-0
Enabled-Healthy
OK
Enabled
1
A
0
Egress
Enabled-Healthy
Non-critical
Enabled
...
1
A
3
Egress
Enabled-Healthy
Non-critical
Enabled
-------------------------------------------------------------------------------
Encl
Ctlr Phy
Type
Status
Elem Status
Disabled
Reason
-------------------------------------------------------------------------------
1
B
0
Drive
Enabled-Healthy
OK
Enabled
1
B
1
Drive
Enabled-Healthy
OK
Enabled
...
1
B
23
Drive
Disabled
OK
Disabled
0x8006
1
B
0
SC-1
Enabled-Healthy
OK
Enabled
1
B
1
SC-1
Enabled-Healthy
OK
Enabled
1
B
0
SC-0
Enabled-Healthy
OK
Enabled
...
1
B
0
Egress
Enabled-Healthy
Non-critical
Enabled
...
1
B
3
Egress
Enabled-Healthy
Non-critical
Enabled
-------------------------------------------------------------------------------
See also
clear expander-status
set expander-fault-isolation
set expander-phy