HP MSA2324sa HP StorageWorks 2300 Family Modular Smart Array CLI reference gui - Page 153

show ports, Media, iSCSI, Target ID, Status, Speed A, Topo C, Width, IP-Ver

Page 153 highlights

show ports Description Shows information about host ports on both controllers. Syntax show ports Output Port Controller ID and port number Media • FC(P): Fibre Channel Point-to-Point • FC(L): Fibre Channel-Arbitrated Loop • FC(-): Not applicable, as when the port is disconnected • SAS: Serial Attached SCSI • iSCSI: Internet SCSI Target ID Enclosure WWN or serial number Status Whether the port is operational, has a problem, or is disconnected Speed (A) Actual host-port link speed, or blank if not applicable. Speed (C) FC and SAS only. Configured host-port link speed: • FC: 2Gb or 4Gb (Gbit/sec) • SAS: 1Gb (Gbit/sec) • Blank if not applicable Topo (C) FC and SAS only. Configured topology Width SAS only. Number of SAS lanes in this port. PID FC and SAS only. Primary ID, or blank if not applicable IP-Ver iSCSI only. IPv4 PIP iSCSI only. Primary IP address SIP iSCSI only. Secondary IP address. This field is only displayed during failover. MAC iSCSI only. Unique Media Access Control (MAC) hardware address, also called the physical address. Example Show port information for a system with two FC ports: # show ports Port Media Target ID Status Speed(A) Speed(C) Topo(C) PID A1 FC(L) 207000C0FF000015 OK 2Gb 2Gb Loop 0 A2 FC(L) 217000C0FF000015 OK 2Gb 2Gb Loop 1 HP StorageWorks 2000 G2 Modular Smart Array CLI Reference Guide 153

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196

HP StorageWorks 2000 G2 Modular Smart Array CLI Reference Guide
153
show ports
Description
Shows information about host ports on both controllers.
Syntax
show ports
Output
Port
Controller ID and port number
Media
FC(P)
: Fibre Channel Point-to-Point
FC(L)
: Fibre Channel-Arbitrated Loop
FC(-)
: Not applicable, as when the port is disconnected
SAS
: Serial Attached SCSI
iSCSI
: Internet SCSI
Target ID
Enclosure WWN or serial number
Status
Whether the port is operational, has a problem, or is disconnected
Speed (A)
Actual host-port link speed, or blank if not applicable.
Speed (C)
FC and SAS only. Configured host-port link speed:
FC:
2Gb
or
4Gb
(Gbit/sec)
SAS:
1Gb
(Gbit/sec)
Blank if not applicable
Topo (C)
FC and SAS only. Configured topology
Width
SAS only. Number of SAS lanes in this port.
PID
FC and SAS only. Primary ID, or blank if not applicable
IP-Ver
iSCSI only. IPv4
PIP
iSCSI only. Primary IP address
SIP
iSCSI only. Secondary IP address. This field is only displayed during failover.
MAC
iSCSI only. Unique Media Access Control (MAC) hardware address, also called the physical
address.
Example
Show port information for a system with two FC ports:
# show ports
Port Media
Target ID
Status
Speed(A) Speed(C) Topo(C) PID
--------------------------------------------------------------------------
A1
FC(L)
207000C0FF000015 OK
2Gb
2Gb
Loop
0
A2
FC(L)
217000C0FF000015 OK
2Gb
2Gb
Loop
1
--------------------------------------------------------------------------