HP MSA2324sa HP StorageWorks 2300 Family Modular Smart Array CLI reference gui - Page 137
Show a range of events logged by controller A, Show all events from 11:59:00 p.m. on Apr 30
View all HP MSA2324sa manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 137 highlights
Example Show the last two events: # show events last 2 Show the last three warning and critical events: # show events last 3 error Show all events from 11:59:00 p.m. on Apr 30, 2008 through 11:59:00 a.m. on May 2, 2008: # show events from 043008235900 to 050208115900 Show a range of events logged by controller A: # show events from-event a100 to-event a123 See also • clear events • set snmp-parameters • show snmp-parameters HP StorageWorks 2000 G2 Modular Smart Array CLI Reference Guide 137
HP StorageWorks 2000 G2 Modular Smart Array CLI Reference Guide
137
Example
Show the last two events:
# show events last 2
Show the last three warning and critical events:
# show events last 3 error
Show all events from 11:59:00 p.m. on Apr 30, 2008 through 11:59:00 a.m. on May 2, 2008:
# show events from 043008235900 to 050208115900
Show a range of events logged by controller A:
# show events from-event a100 to-event a123
See also
•
clear events
•
set snmp-parameters
•
show snmp-parameters