HP MSA2324sa HP StorageWorks 2300 Family Modular Smart Array CLI reference gui - Page 118
show auto-write-through-trigger, show awt, Description, Syntax, Example, See also
View all HP MSA2324sa manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 118 highlights
show auto-write-through-trigger Description Shows the system's write-through trigger settings. When a trigger condition occurs and the trigger is enabled, the RAID controller cache mode changes from write-back to write-through. Alias: show awt. Syntax show auto-write-through-trigger Example Show the system's auto-write-through trigger settings: # show auto-write-through-trigger Auto Write-Through Triggers Controller Failure: Disabled SuperCap Failure: Enabled CompactFlash Failure: Enabled Power Supply Failure: Disabled Fan Failure: Disabled Temperature Exceeded: Disabled Partner Notify: Disabled Auto Write Back: Enabled See also • set auto-write-through-trigger show awt See show auto-write-through-trigger. 118
118
show auto-write-through-trigger
show awt
See
show auto-write-through-trigger
.
Description
Shows the system's write-through trigger settings. When a trigger condition occurs and the trigger is
enabled, the RAID controller cache mode changes from write-back to write-through. Alias:
show
awt
.
Syntax
show auto-write-through-trigger
Example
Show the system's auto-write-through trigger settings:
# show auto-write-through-trigger
Auto Write-Through Triggers
---------------------------
Controller Failure: Disabled
SuperCap Failure: Enabled
CompactFlash Failure: Enabled
Power Supply Failure: Disabled
Fan Failure: Disabled
Temperature Exceeded: Disabled
Partner Notify: Disabled
Auto Write Back: Enabled
See also
•