HP MSA2324sa HP StorageWorks 2300 Family Modular Smart Array CLI reference gui - Page 156

show redundancy-mode, Serial Number

Page 156 highlights

show redundancy-mode Description Shows the redundancy status of the system. Syntax show redundancy-mode Output Redundancy Mode The redundancy mode, also called the operation mode. • Active-Active ULP: Both controllers are active using ULP (Unified LUN Provisioning). • Single-Controller: The enclosure contains a single controller using ULP. Redundancy Status • Redundant: Both controllers are operational. • Operational but not redundant: In active-active mode, one controller is operational and the other is offline. In single-controller mode, the controller is operational. Controller ID Status • Operational: The controller is operational. • Down: The controller is installed but not operational. • Not Installed: The controller is not installed. Controller ID Serial Number • Controller module serial number • Not Available: The controller is down or not installed. Example Show the redundancy status of a dual-controller system where controller A is offline: # show redundancy-mode System Redundancy Redundancy Mode: Active-Active ULP Redundancy Status: Operational but not redundant Controller A Status: Down Controller A Serial Number: Not Available Controller B Status: Operational Controller B Serial Number: 00C0FF0A4326 Show the redundancy status of an operational dual-controller system using ULP: # show redundancy-mode System Redundancy Redundancy Mode: Active-Active ULP Redundancy Status: Redundant Controller A Status: Operational Controller A Serial Number: 00C0FF0A4318 Controller B Status: Operational Controller B Serial Number: 00C0FF0A4326 156

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196

156
show redundancy-mode
Description
Shows the redundancy status of the system.
Syntax
show redundancy-mode
Output
Redundancy Mode
The redundancy mode, also called the operation mode.
Active-Active ULP
: Both controllers are active using ULP (Unified LUN Provisioning).
Single-Controller
: The enclosure contains a single controller using ULP.
Redundancy Status
Redundant
: Both controllers are operational.
Operational but not redundant
: In active-active mode, one controller is operational and
the other is offline. In single-controller mode, the controller is operational.
Controller
ID
Status
Operational
: The controller is operational.
Down
: The controller is installed but not operational.
Not Installed
: The controller is not installed.
Controller
ID
Serial Number
Controller module serial number
Not Available
: The controller is down or not installed.
Example
Show the redundancy status of a dual-controller system where controller A is offline:
# show redundancy-mode
System Redundancy
-----------------
Redundancy Mode: Active-Active ULP
Redundancy Status: Operational but not redundant
Controller A Status: Down
Controller A Serial Number: Not Available
Controller B Status: Operational
Controller B Serial Number: 00C0FF0A4326
Show the redundancy status of an operational dual-controller system using ULP:
# show redundancy-mode
System Redundancy
-----------------
Redundancy Mode: Active-Active ULP
Redundancy Status: Redundant
Controller A Status: Operational
Controller A Serial Number: 00C0FF0A4318
Controller B Status: Operational
Controller B Serial Number: 00C0FF0A4326